Trunnion Tab
- Last UpdatedNov 13, 2023
- 3 minute read
By default, a separate tab displays on the Support Editor window for the trunnion and each of the associated ancillaries.
The 2D View part of the Support Editor window allows you to modify the size and position of the trunnion and each of the associated ancillaries.

The values in the text fields can be modified to define the size and position of a trunnion.
|
|
Select default tab |
Click to display the default tab. The default tab is the first tab created and is positioned furthest left. |
|
|
Select ancillary tab by canvas pick |
Click to display the tab for an identified ancillary using a cursor pick in the 3D view. You are prompted to Identify ancillary in current support |
|
|
2D/3D View |
Click to display a 3D view of the trunnion. Refer to 3D View Tab for further information. |
|
Dimensions |
Input values in the Dimensions fields to explicitly modify the dimensions of the trunnion. If a value is entered that is outside the allowable range, an error message displays summarizing the problem.
|
|
|
Bore |
Select from the drop-down list to define the bore size of the trunnion leg. |
|
|
Plate |
Select from the drop-down list to define a plate for the Trunnion. |
|
|
|
Set Trunnion Height by pick |
Click to modify the height of the trunnion using a cursor pick in the 3D view. For example to align to a floor or wall element. You are prompted to Identify element to set trunnion to |
|
|
Set Trunnion Material |
Allows you to modify the material for the trunnion. Refer to Modify Trunnion Material for further information. |
|
|
Create Base Component |
Allows you to associate an additional ancillary with the base of the trunnion. Click to display the Ancillary Selection window. The Ancillary Selection window displays all of the available/unavailable ancillaries. Refer to Ancillary Selection for further information. The associated ancillary displays as a separate tab. |
|
|
Component - Click to Support Pipe |
Allows you to define the position of the trunnion. Click to move the trunnion from an elbow, tee, bend or reducer to the tube of the pipe. By default, the trunnion size and the associated ancillaries are modified by the supports application, if required. |
|
|
Pipe - Click to Support Component |
Allows you to define the position of the trunnion. Click to position the trunnion from the tube of the pipe to an elbow, tee, bend or reducer. By default, the trunnion size and the associated ancillaries are modified by the supports application, if required. |
|
Distance/Clearance |
Allows you to position the trunnion. The functionality is identical to the positioning of a preliminary support. Refer to Preliminary Tab for further information. |
|
|
Distance from Support/Distance from pipe element |
Allows you to position of the trunnion. The functionality is identical to the positioning of a preliminary support. Refer to Preliminary Tab for further information. |