Generating a Report from Existing Clash Data
- Last UpdatedFeb 19, 2025
- 1 minute read
Keywords
OUTPUT
Description
The report generated in response to an OUTPUT command has exactly the same format, determined by any current reporting options which have been set, as that generated in response to a CHECK command. The difference is that the check options, touch and clearance values, obstruction list etc. which apply to the Output report are those current when the clash run was carried out; these need not be current when the OUTPUT command is given.
Examples |
|
|---|---|
|
OUTPUT CLASHES /ZONE1.PIPES OUTPUT /PUMP1 /PUMP2 /VESS2 OUTPUT /GROUP.MOD2 OUTPUT LEAVE TUBE FROM /FLAN2 IARRIVE TUBE TO /VALV5 |
|
|
These commands output reports of known clashes involving the specified items in each case |
|
|
OUTPUT |
Outputs a complete report of all clash data currently held in memory |
Command Syntax
>--- OUTput ---+--- CLAshes ---.
| |
‘---------------+--- <clid> --->
where <clid> (clashing item identifier) is
>---+--- ILEAve ---.
| |
|--- IARRIVE --|
| |
|--- HEAD -----|
| |
|--- TAIL -----+--- TUBe ---.
| | |
| |--- ROD ----|
| | |
| ‘------------+--- OF -----.
| | |
| |--- FROM ---|
| | |
| |--- TO -----|
| | |
| ‘------------+
| |
‘----------------------------------------+--- <gid> --->