Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

THRE flat oval requirements

  • Last UpdatedAug 25, 2025
  • 2 minute read

This topic describes the specification requirements for flat oval thee-way (THRE) components.

Parameter description requirements

  • Parameter #1 = Width (arrive and leave)

  • Parameter #2 - Height (arrive and leave)

  • Parameter #3 = Width of branch

  • Parameter #4 = Height of branch

    Note:
    Where the Arrive and Leave are different sizes, additional parameters are required. Normally the Width and Height parameters can be used for both Arrive and Leave sizes.

Data set requirements

For information about data set requirements that apply for all flat oval components, refer to Flat oval component requirements.

The following requirements are in addition to the data references that are created for parameters.

KEY

Type

Description

Default ( /Expression **)

SHAP

Expression

Duct shape

‘OVAL’

AARR

Distance

Width of arrive

PARA[1 ]

BARR

Distance

Height of arrive

PARA[2 ]

ALEA

Distance

Width of leave

PARA[1 ]

BLEA

Distance

Height of leave

PARA[2 ]

ABRA

Distance

Width of branch

PARA[3 ]

BBRA

Distance

Height of branch

PARA[4 ]

** Where the Default value is set to a parameter, the Expression value must be set to the same parameter. This is applicable for all component types.

P-point requirements

For information about P-point requirements that apply for all flat oval components, refer to Flat oval component requirements.

The following table shows the additional required P-points:

Type

Connection Type (PCON)

Bore (PBOR)

Axis Direction (PAXI)

PZ Axis (PZAXI)

Point Width (PWID)

Point Height (PHEI)

PDShape attribute

AllAngle attribute

1

PTAX

OVAL

(RPRO AARR + RPRO BARR)

-Z

Y

RPRO AARR

RPRO BARR

OVAL

180

2

PTAX

OVAL

(RPRO ALEA + RPRO BLEA)

Z

Y

RPRO ALEA

RPRO BLEA

OVAL

180

3

PTMI

OVAL

(RPRO ALEA + RPRO BLEA)

X

Y

RPRO ABRA

RPRO BBRA

OVAL

180

61

PTMI

0

0

Y

unset

unset

unset

0

unset

62

PTMI

0

0

Y

unset

unset

unset

0

unset

63

PTMI

0

0

Y

unset

unset

unset

0

unset

64

PTMI

0

0

Y

unset

unset

unset

0

unset

The P-points are arranged as shown in the following graphic:

Specification requirements

The following specification headings are required:

  • Type (TYPE)

  • Duct Shape (PSHA)

  • Duct Width 1 (PWID1)

  • Duct Height 1 (PHEI1)

  • Duct Width 2 (PWID2)

  • Duct Height 2 (PHEI2)

  • Duct Width 3 (PWID3)

  • Duct Height 3 (PHEI3)

Duct Width1 and Duct Height1 correspond to the arrive of the component (P1).

Duct Width2 and Duct Height2 correspond to the leave of the component (P2).

Duct Width3 and Duct Height3 correspond to the offline connection of the component (P3).

Note:
In some cases, the above recommendations are not followed by the AVEVA supplied flat oval specifications or AVEVA legacy custom specifications, and they are not intended to be used as a template on how to set up new custom specifications.