Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

CLASSIFICATION

  • Last UpdatedJan 23, 2023
  • 1 minute read

The classification definition file defines the content of the secondary attributes window, which serves to enter the radio-protection classification. Significant lines start with the # character.

The two first lines give the names of the User Defined Attribute (UDA) parameters which store values. These UDAs are no longer used. Following lines give the choice list of proposed values to the user.

----------------------------------------

-- UDA names for Shut Down values

----------------------------------------

#:nrmdddcla_s#:nrmindbio_s#:nrmddcoul_s

----------------------------------------

-- UDA names for production values

----------------------------------------

#:nrmdddcla_p#:nrmindbio_p#:nrmddcoul_p

----------------------------------------

-- Class

Value

Colour

----------------------------------------

#

0.02A

#

0.0002 mSv/h

# GREEN

#

0.25A

#

0.0025 mSv/h

# GREEN

#

0.5A

#

0.005 mSv/h

# GREEN

#

0.75A

#

0.0075 mSv/h

# GREEN

#

1A

#

0.01 mSv/h

# GREEN

#

2.5A

#

0.025 mSv/h

# GREEN

#

4A

#

0.04 mSv/h

# YELLOW

#

B

#

0.1 mSv/h

# YELLOW

#

2B

#

0.2 mSv/h

# YELLOW

#

C

#

1 mSv/h

# YELLOW

#

2C

#

2 mSv/h

# YELLOW

#

D

#

10 mSv/h

# ORANGE

#

3D

#

30 mSv/h

# ORANGE

#

E

#

100 mSv/h

# ORANGE

#

3E

#

300 mSv/h

# RED

#

F

#

1 Sv/h

# RED

#

3F

#

3 Sv/h

# RED

#

G

#

10 Sv/h

# RED

#

3G

#

30 Sv/h

# RED

#

H

#

100 Sv/h

# RED

#

3H

#

300 Sv/h

# RED

#

I

#

1000 Sv/h

# RED

#

3I

#

3000 Sv/h

# RED

#

K

#

10000 Sv/h

# RED