Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

Combined Pipework Tolerance and Tube Length Options

Combined Pipework Tolerance and Tube Length Options

  • Last UpdatedFeb 19, 2025
  • 1 minute read

Keywords

TOLERANCE OPTIONS DEFAULT

Description

The OPTIONS command allows the user to reset defaults for, or query, all data consistency checking options for Tubes at the same time.

Example

TOL OPTIONS DEFAULT

Resets the following data-checking parameters:

  • Offset tolerance to 1 mm

  • Angle tolerance to 0.0573 degrees

  • Ratio tolerance to 0.001

  • Maxangle setting to 90 degrees

  • Minimum tube length for all bores to 100 mm

  • ATTACHECK option to ON

Command Syntax

>-- TOLerance OPTions DEFault -->

Querying

>-- Query TOLerance OPTions -->

Outputs the current settings for all data checking parameters. The parameters are output in the current units.

Querying Examples

With all default settings in force, the output resulting from a Q TOL OPT command will show one of the following sets of values (depending upon the current units):

MM Bores and Distances

Minimum tube length : 100 mm
Tolerance Offset    : 1 mm
Tolerance Angle     : 0.0573
Tolerance Ratio     : 0.001
Maximum Angle       : 90
Atta checking       : ON

INCH Bores and Distances

Minimum tube length : 3.9 in
Tolerance Offset    : 0 in
Tolerance Angle     : 0.0573
Tolerance Ratio     : 0.001
Maximum Angle       : 90
Atta checking       : ON

FINCH Bores and Distances

Minimum tube length : 3.15/16
Tolerance Offset    : 0.1/32
Tolerance Angle     : 0.0573
Tolerance Ratio     : 0.001
Maximum Angle       : 90
Atta checking       : ON