Combined Pipework Tolerance and Tube Length Options
- Last UpdatedFeb 19, 2025
- 1 minute read
Keywords
TOLERANCE OPTIONS DEFAULT
Description
The OPTIONS command allows the user to reset defaults for, or query, all data consistency checking options for Tubes at the same time.
Example |
|
|---|---|
|
TOL OPTIONS DEFAULT |
Resets the following data-checking parameters:
|
Command Syntax
>-- TOLerance OPTions DEFault -->
Querying
>-- Query TOLerance OPTions -->
Outputs the current settings for all data checking parameters. The parameters are output in the current units.
Querying Examples
With all default settings in force, the output resulting from a Q TOL OPT command will show one of the following sets of values (depending upon the current units):
MM Bores and Distances
Minimum tube length : 100 mm
Tolerance Offset : 1 mm
Tolerance Angle : 0.0573
Tolerance Ratio : 0.001
Maximum Angle : 90
Atta checking : ON
INCH Bores and Distances
Minimum tube length : 3.9 in
Tolerance Offset : 0 in
Tolerance Angle : 0.0573
Tolerance Ratio : 0.001
Maximum Angle : 90
Atta checking : ON
FINCH Bores and Distances
Minimum tube length : 3.15/16
Tolerance Offset : 0.1/32
Tolerance Angle : 0.0573
Tolerance Ratio : 0.001
Maximum Angle : 90
Atta checking : ON