Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

Note: 3 /DRA/MAS/H&S_A2/Supported_Items

  • Last UpdatedAug 13, 2025
  • 1 minute read

The Note displays a table that lists the pipes that are being supported.

TEXP 1

BTEX set to

BOM:SIB

Not used at this release.

TEXP 2

BTEX set to

HEADER_POS:value1,value2

where value1 and value2 define the position of a SLAB that references the supported item table symbol template (SYTM). The origin of the SYTM is the upper left corner of the table.

TEXP 3

BTEX set to

LABEL_POS:value1,value2

where value1 and value2 define the position of the first SLAB in the support item table. The position is a distance from the lower left corner of the owning BACK.

TEXP 4

BTEX set to

TILE_X:value

where value is the horizontal distance between the reference SLABs in the support item table.

TEXP 5

BTEX set to

TILE_Y:value

where value is the vertical distance between the reference SLABs in the support item table.

TEXP 6

BTEX set to

TILE_MAX:value

Not used at this release.

TEXP 7

BTEX set to

TAGGING:name

The LABEL TAGR defines criteria for the Support Table BOM and references that specific label template.

TEXP 8

BTEX set to

TITLE:text

where text is used in the log file to mark the start of messages relating to symbolic labels in the supported item layer owned by the View.