Layout Space Arrangement
- Last UpdatedNov 30, 2023
- 2 minute read
Attribute on element (SPMLSA).
|
Name |
Description |
|
SPMPU |
Purpose code. |
|
DESC |
Description. |
|
SPMCTY |
Content type. System defined values are:
|
|
SPMCDE |
Content description. |
|
SPMRFA |
Required floor area. |
|
SPMRDH |
Required deck hight. |
|
SPMTIC |
Compartment tightness code. System defined values are:
|
|
SPMTID |
Compartment tightness description. |
|
SPMNOC |
Noise category code. System defined values are:
|
|
SPMNOD |
Noise category description. |
|
SPMTHC |
Thermal insulation code. |
|
TPMTHD |
Thermal insulation description. |
|
SPMACC |
Access authorization code. System defined values are:
|
|
SPMACD |
Access authorization description. |
|
SPMSAC |
Safety category code. System defined values are:
|
|
SPMSAD |
Safety Category description. |
|
SPMSEC |
Security classification code. System defined values are:
|
|
SPMSED |
Security classification description. |
|
SPMLSC |
Space category. |
|
SPMEPC |
Estimated power consumption. |
|
SPMEHC |
Estimated HVAC capacity. |
|
SPMEWC |
Estimated weight of space contents. |
|
SPMCWC |
Calculated weight of space contents. |
|
SPMEWS |
Estimated weight of space steel structure. |
|
SPMCWS |
Calculated weight of space steel structure. |
|
SPMCOS |
Calculated center of steel structure. |
|
SPMEWL |
Estimated steel fillet weld length of space contents. |
|
SPMCWL |
Calculated steel filet weld length of space contents. |
|
SPMEWB |
Estimated steel butt weld length of space contents. |
|
SPMCWB |
Calculated steel butt weld length of space contents. |
|
SPMEAS |
Estimated steel paint areas of space contents. |
|
SPMCAS |
Calculated steel paint areas of space contents. |
|
SPMRSE |
Required Services. |
|
TEMP |
Temperature. |
|
MAXTEM |
Maximum temperature. |
|
MINTEM |
Minimum temperature. |
|
HUMIDI |
Design humidity. |
|
MAXHUM |
Maximum humidity. |
|
MINHUM |
Minimum humidity. |
|
PRES |
Pressure. |
|
MAXPRE |
Maximum pressure. |
|
MINPRE |
Minimum pressure. |
|
MAXWAT |
Maximum water level. |
|
AIRCHA |
Air change rate. |
|
OCCUPA |
Occupancy. |
|
LIGHTI |
Lighting requirements. |
|
MAXARE |
Maximum area. |
|
MINARE |
Minimum area. |
|
MAXVOL |
Maximum volume. |
|
MINVOL |
Minimum volume. |
Attributes on element (SPMLFA).
|
Name |
Description |
|
SPMFCL |
Insulation code. |
Attributes on element (SPMPSA).
|
Name |
Description |
|
FACODE |
Face code definition. |
|
SPMEAS |
Estimated steel paint areas of space contents. |
|
SPMCAS |
Calculated steel paint areas of space contents. |
Attributes on element (SPMPFA).
|
Name |
Description |
|
FACODE |
Face code definition. |