Export Geometry from E3D to Rohr2
- Last UpdatedJan 24, 2023
- 2 minute read
Exports geometry and material from AVEVA E3D Design to Rohr2.

The Export Data part of the AVEVA Pipe Stress Interface - R2 window displays the pipes/ branches for export.
When collecting the pipes of a pipe system for export to Rohr2, it is mandatory that the pipes are in a network. None of the branches may be isolated by the rest of the pipe system.
The current export list content is displayed and highlighted in the 3D view. The content can be checked for completeness. For example, a branch may not be collected because of missing references.
The highlight color can be modified. For further information, refer to Data Transfer Settings.
|
List Pipes / List Branches |
Displays branches or pipes for export. |
|
Add CE |
Adds all branches below the current element to the export list. Note: It is not checked if all elements are part of a single network or all branches are connected correctly. |
|
Add Network |
Adds all branches to the export list which are connected directly or indirectly to the current element. |
|
Remove CE |
Removes all branches below the current element from the export list. |
|
Remove Network |
Removes all branches from the export list which are connected directly or indirectly to the current element. |
|
Remove Selected |
Removes the selected elements from the export list. |
|
Load Pipe List |
Populates the export list with the content of a previously saved file. |
|
Save Pipe List |
Saves the content of the export list to a file. |
|
Modify Hangers |
Assigns hanger types to single hangers. Refer to Modify Hangers for further information. |
|
Show Limits |
Sets the limits of the 3D view to the content of the export list. |
|
Show Labels |
Displays selected pipe supports in the 3D view. |
|
Label Types |
Displays selected support attributes. The option becomes active when Show Labels is selected. |
|
Apply |
Exports all selected branches. After collecting all geometry and material data, the file browser is opened in order to define the name and location of the transfer file. The file extension must be .ntr. Additionally, a second file with the extension .ntrerror is created in the transfer directory. The log file contains all export error information. |
|
Cancel |
Discards any changes and closes the AVEVA Pipe Stress Interface - R2 window. |