What the Checking Facility Does
- Last UpdatedJan 13, 2023
- 2 minute read
The following tests may be carried out:
At Specification (SPEC) level
-
Check that no question in the specification is repeated.
-
Check that one question in the specification is TYPE.
-
From the TYPE reference, check that the Generic Type (GTYPE) of the Piping Component (COMP) has the same setting.
-
From the TYPE reference, check that the Symbol Key (SKEY) setting of SDTE is correct.
-
From the TYPE reference, check that the point set has the correct geometry, as required by Isodraft.
At Specific Component (SPCO) level
-
Check that all of the following reference attributes are set: Catalog Reference (CATREF), DETAIL, MATX, CMPR, BLTREF. (The BLTREF need be set only if the connection type begins with F or L.)
At COMP or equivalent level
-
Check that there is a valid PTREF and GMREF.
-
At a PTSE, check that P-points are set and that there are no duplicate numbers.
-
At a 3D Geomset Element (GMSE), check that there are primitives set and that they are not degenerate. Check also that no invalid P-point numbers or parameters are used. Note that this test uses Catalog parameters, so that if a primitive is constructed only from design and insulation parameters, spurious warnings will be generated.
-
Check that each P-point connection type exists in the Connection Compatibility (COCO) tables. P-points used for construction purposes can have connections of 0.0, NUL or NULL. The connection type will not be checked for validity for a specific type of component.
-