Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

INSULATIONCONTROL

  • Last UpdatedAug 28, 2025
  • 1 minute read

Function:

Specifies whether or not insulation is to be plotted.

Description:

Any piping component that has its ISPEC attribute set may be shown insulated. The start and end points of insulated components will be shown on the isometric.

Insulation and tracing can be shown:

  • On tubing only

  • On tubing and pipe components

The name of the insulation and/or tracing specification will be shown in the title block.

Examples:

INSU ON

Display insulation.

INSU TUBE

Show insulation on the tube only, not on the pipe components.

INSU ALL

Show insulation on both tube and components.

INSU OFF

Suppress the display of insulation.

The default is INSULATIONCONTROL TUBE.

Related Commands:

TRACINGCONTROL

Command Syntax:

>------ INSUlationcontrol ----+---- ON* ----.
                              |             |
                              |---- TUBE ---|
                              |             |
                              |---- ALL ----|
                              |             |
                              ‘---- OFF ----+--->

Querying:

Q INSUlationcontrol

Q OPTions