Configure the Flow Rate Source tab of the Pipe Segment record
- Last UpdatedApr 24, 2025
- 1 minute read

Note: If a pipe segment has the Flow Rate Source Path field configured correctly, the instantaneous flow rate of the segment will come from the source reading directly—and not from the internal flow rate calculation. The segment flow rate affects the Hydraulic Profile and ETA calculations performed by the Batch Tracking application.
|
BTC Attributes |
Flow Rate Source tab, pipe_segment Row Edit dialog |
Description |
|
PIPE |
Pipe Segment |
The pipe name. |
|
GROUP |
Group |
The group name. For more information about groups, see Configure the Batch Estimated Time of Arrival (ETA) tab of the Node record. |
|
Dataset |
Dataset defined by the pipeline record. This typically is not defined by a BTC attribute. |
|
|
SECT |
Section |
A logical grouping of pipe segments. |
|
UNITPROF |
Input Unit Profile |
The unit profile that the segment uses for display units and conversions. |
|
PRIDISPLAY |
Priority Display |
The easy eXtended Operator Station (ezXOS) display name that can be accessed from the Alarm Summary when this point generates an alarm. |
|
FLOWRATESOURCEPATH |
Flow Rate Source Path |
Path to the flow rate source to override the default flow rate calculations for the pipe segment. The field must be a numeric type (that is, rate.pointName.currate). |