Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Pipeline Operations for Liquids

Understand the common calculation of Corrected Composite Meter Factor (CCMF)

Understand the common calculation of Corrected Composite Meter Factor (CCMF)

  • Last UpdatedApr 24, 2025
  • 1 minute read

Note: The API version is configured during the installation procedure, and is not configurable in Advanced Database Editor (ADE).

Most netting types use this method of calculating the Corrected Composite Meter Factor (CCMF). The amount of rounding and the steps where rounding is applied depends on the API version in use.

Calculation:

  1. If the version is API2004:

    1. CCMF = CTPL x MCF

    2. Round CCMF to 5 decimals, or to the specified number of decimals (for example, Batch Tracking linepack specifies 7 decimals).

    3. In all standard cases, GSV = GUV x CCMF

  2. If the version is API1980:

    1. Compute CCMF = CTL x CPL x MCF

    2. Round the CCMF results to 4 decimals, or to the specified number of decimals.

    3. In all standard cases, GSV = GUV x CCMF

Standard Calculations

For standard calculations, CCMF is generated and rounded as described above.

Gross Standard Volume = Gross Uncorrected Volume x CCMF

The standard algorithm is used in the following instances:

  • PRODUCTS

  • CRUDES

  • MBTE

  • TBA

  • BENZENE

  • ALKYLATE

  • RAFFINATED

  • TOLUENE

  • NGL

  • ETHANE – HI/LOW PURITY

  • PROPANE

  • BUTANE

  • ISOBUTANE

  • NATURAL-GAS

  • OP400

  • FEEDSTOCKS

  • PYROLYSIS-H/L

  • CO2

  • CONDENSATE

Hydrogen

For hydrogen, no application of correction factors is made.

In this case, Corrected Volume = Uncorrected Volume.

In This Topic