Understand the Flow Network Export Command Line tool error codes
- Last UpdatedApr 24, 2025
- 1 minute read
The following table describes the error codes associated with the Flow Network Export Command Line tool.
|
Error Code |
Description |
Error Message |
|---|---|---|
|
0 |
Command line execution was successful. |
|
|
1 |
Invalid arguments. -f and at least one of the following parameters are required: -u / -j / -e |
Invalid arguments, File name and at least one argument in [ExportService, json path and Update] are required. |
|
2 |
No .simx file exists with the given name. Note: By default, the AVEVA Process Simulation (APS) folder path referenced is C:\Users\dnaDeveloper\AppData\Local\SimSci\SimCentral\Sims, where <dnaDeveloper> refers to the user role used to install APS. |
The simx file <PipelineName> does not exist in <APS Folder Path>. |
|
3 |
The pipeline does not exist in the workspace or was not created or loaded successfully. |
Invalid Pipeline <Pipeline Name>. |
|
4 |
Unexpected error. This error most likely occurred during the RealTime call. |
An unexpected error happened while processing the file: <exceptionMessage> |
|
5 |
Argument parsing error. Note: When this error code is returned, the Flow Network Export Command Line tool help is also displayed. |