List of available Action Sequence functions
- Last UpdatedApr 24, 2025
- 2 minute read
The following Action Sequence functions are immediately executed—no prompt or confirmation is required. For example, Ticket Start will always start the next pending ticket, without regard for whether the product is compatible with the current ticket or not.
|
Function |
Description |
|---|---|
|
Accumulator |
|
|
Inhibit |
Updates the Accumulator record by setting the Inhibit flag to Yes. |
|
Enable |
Updates the Accumulator record by setting the Inhibit flag to No. |
|
BatchXfer |
|
|
Inhibit |
Updates the Batch Transfer record by setting the Inhibit flag to Yes. |
|
Enable |
Updates the Batch Transfer record by setting the Inhibit flag to No. |
|
Set Receipt |
Updates the Batch Transfer record by setting the Fixed Assignment Type to Receipt. |
|
Set Delivery |
Updates the Batch Transfer record by setting the Fixed Assignment Type to Delivery. |
|
Ticket Start |
Executes a Ticket Start command on the Batch Transfer record. |
|
Ticket Split |
Executes a Ticket Split command on the Batch Transfer record. |
|
Ticket Stop |
Executes a Ticket Stop command on the Batch Transfer record. |
|
Update Schedule |
Retrieves the pending tickets from the Historical BatchSchedule table into the RealTime database. |
|
Fetch Schedule |
Fetches the remote pending tickets. This requires the plugin “RemoteTicketingAssemblies” to be set in the Batch Transfer plugin configuration section. |
|
Toggle Auto-Switch |
Changes the status of the Auto Switch field on the Batch Transfer record. If the current value is Yes, it will change it to No and vice versa. |
|
Pipeline Monitor (PLM) |
|
|
Inhibit |
Updates the PLM record by setting the Inhibit flag to Yes. |
|
Enable |
Updates the PLM record by setting the Inhibit flag to No. |
|
Pipeline Reset |
Executes the PIPELINE RESET command on the PLM. |
|
Reset All |
Executes the RECORD RESET command on the PLM. |
|
PLM Volume Device |
|
|
Inhibit |
Updates the PLM Volume Device record by setting the Inhibit flag to Yes. |
|
Enable |
Updates the PLM Volume Device record by setting the Inhibit flag to No. |
|
Set Direction In |
Updates the PLM Volume Device record by setting the Input/Output field to In. |
|
Set Direction Out |
Updates the PLM Volume Device record by setting the Input/Output field to Out. |