AVEVA Pipeline Operations for Liquids

Automatic pump shutdown using POIs

  • Last UpdatedApr 24, 2025
  • 1 minute read

The Line Blockage application monitors POIs in order to determine if a shutdown is required. When the underlying status or multistate point is toggled by an external application to indicate an abnormal condition, the Line Blockage application will shut down pumps upstream or/and downstream of that POI. The decision to shut down upstream pumps only, downstream pumps only or both depends on the configuration of the individual pumps. For more information on Pump Blocked Rules, see Understand pump blockage definition.

Note: Automatic pump shutdown using POIs will only generate events. If the Ignore flag is activated for a POI, an event indicating that the pump will not shut down is generated. For more information, see Understand Pump Line Blockage Events.