Understand the volume corrections applied according to netting type
- Last UpdatedApr 24, 2025
- 1 minute read
The following table describes the Correction Factors used by AVEVA Pipeline Operations for Liquids.
|
Correction Factor |
Acronym |
Definition |
|---|---|---|
|
CTL |
Corrected Temperature Liquids |
The Corrected Temperature Liquids correction factor originates from the temperature correction table dropdown menu on the prodgroup Row Edit dialog. |
|
CPL |
Corrected Pressure Liquids |
The Corrected Pressure Liquids correction factor originates from the pressure correction table dropdown menu on the prodgroup Row Edit dialog. |
|
CTPL |
Combined Temperature and Pressure Liquids |
The CTPL value is calculated as follows: CTPL = CTL x CPL This is always used for API2004. |
|
MCF |
Mechanical Correction Factor |
The Mechanical Correction Factor is applied when volume is measured by a turbine meter. This value is set to one when volume measurement does not come from a turbine meter. |
|
Corrected Composite Meter Factor |
Corrected Composite Meter Factor |
Composite correction factor. |
|
Base Density |
N/A |
Product Density at the standard temperature and pressure. |