Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Pipeline Operations for Liquids

ProductInjectionGlobalPermissive Business Logic Tier (BLT)

ProductInjectionGlobalPermissive Business Logic Tier (BLT)

  • Last UpdatedApr 24, 2025
  • 1 minute read

The Product Injection Global Permissive (ProductInjectionGlobalPermissive) Business Logic Tier (BLT) sets a field (destination.GlobalPermissiveEnabled) on a set of Product Transfer Checking (flowXfer) records that are linked to the provided pipeline record name. This field is important as it is checked during the execution of the productInjectionVerification BLT prior to activating any logic.

This BLT can be used if there is a need to define custom logic on when to enable or disable Product Injection Verification and Control on a given pipeline.

The following table details the input parameters for the ProductInjectionGlobalPermissive BLT.

Argument

Type

Description

pipelineName

String

The name of the pipeline on which to search. flowXfer records that have a Node reference on this pipeline will be modified.

enable

Boolean

Pass in true to enable automatic Product Injection Verification and Control, and false to disable automatic Product Injection Verification and Control.

The following table details the output parameter for the ProductInjectionGlobalPermissive BLT.

Argument

Type

Description

message

String

The error message indicating the reason for the processing failure.

A blank error message indicates the request was successfully processed.