AVEVA Pipeline Operations for Liquids

Configure the ProtectedLocation Row Edit: Main tab

  • Last UpdatedApr 24, 2025
  • 2 minute read

Use the Main tab in the ProtectedLocation Row Edit dialog to configure basic properties of the point.

16.2

The following table details the items on Main tab of the ProtectedLocation Row Edit dialog.

Item

Description

Name

Type the name of the new record.

Note: If you want to edit an existing record, click (...) and select the name of the protectedLocation record from the protectedLocation Select dialog.

Description

Type a description of the record. The Description can be up to 47 characters in length. This field is for information purposes only and can be used to describe the record, its association with other records, or any other textual information. The Name and Description configured for a record appear in the summary tables in easy eXtended Operator Station (ezXOS).

Group

Click (...) and select the name of the group this record belongs to from the Group Select dialog. Groups are assigned to closely related records.

Dataset

Click (...) and select the name of the dataset you want to associate with this record from the Dataset Select dialog.

A dataset contains privileges assigned for each system and mode. Once a record is assigned to a data set value, the dataset can only be changed to a value for which the system has a privilege record. A record’s dataset cannot be changed in such a way that the system can no longer access the record.

Base Message

Click (...) and select the message associated with the record from the Message Select dialog.

Flow Network Location

Type or select the name of the Flow Network (the fnet record) you want to associate with this record.

Note: This is a required field.

Priority Display

Specify the graphic you want to be associated with the priority display button on an ezXOS Control dialog.