AVEVA Pipeline Operations for Liquids

Weighted average calculations for a Batch Transfer

  • Last UpdatedApr 24, 2025
  • 2 minute read

Weighted average values for Batch Transfers reset with every new batch.

To calculate a weighted average flow rate, the system sums the weighted average flow rates of the Batch Transfer Sources:

Embedded Image (65% Scaling) (LIVE)

To calculate a weighted average Meter Correction Factor (MCF), the system uses the Indicated Volume (IV) as a basis for aggregating the weighted average MCF's of the Batch Transfer Sources:

Embedded Image (65% Scaling) (LIVE)

To calculate a weighted average for Temperature (T), Pressure (P), Observed Density (OD), Corrected Density (D), Correction for Temperature of a Liquid (CTL), and the Correction for Pressure of a Liquid (CPL), the system uses the Gross Volume (GV) as a basis for aggregating the weighted averages of the Batch Transfer Sources. GV is the actual volume at flowing temperature and pressure after being corrected by the meter factor.

Embedded Image (65% Scaling) (LIVE)

Where Y is one of the following: Temperature (T), Pressure (P), Observed Density (OD), Corrected Density (D), Correction for Temperature of a Liquid (CTL), or the Correction for Pressure of a Liquid (CPL).

To calculate a weighted average for Viscosity and Sulphur, the system uses the Gross Volume (GV) as a basis for the calculations. The following procedure is used:

Embedded Image (65% Scaling) (LIVE)

Embedded Image (65% Scaling) (LIVE)

Where Y is Sulphur or Viscosity.

To calculate a weighted average Sediment and Water Percent (S&W), the system uses the Gross Standard Volume (GSV) as a basis for the calculations. The following procedure is used:

Embedded Image (65% Scaling) (LIVE)

Embedded Image (65% Scaling) (LIVE)