AVEVA Pipeline Operations for Liquids

FlowNetworkStopStations Business Logic Tier (BLT)

  • Last UpdatedApr 24, 2025
  • 2 minute read

You can use the FlowNetworkStopStations Business Logic Tier (BLT) to execute the Shutdown Sequence action for all pumps in the specified stations. For more information, refer to the AVEVA Pipeline Operations for Liquids Administrator documentation.

The following table details the parameters of the FlowNetworkStopStations BLT.

Name

Type

Optional

Output

Description

FlowNetworkName

string

False

False

This input parameter specifies the name of the Flow Network containing the stations to shut down.

Stations

string

False

False

This parameter specifies the list of stations to shutdown (separated by space or comma).

Result

int

False

True

This parameter indicates the execution result. It will return a 0 for success and a non-zero value if an error occurs.

Message

string

False

True

This output parameter will provide a result message after execution.

FlowNetworkStopStations BLT Programming Example

The following is an example of how you can program using the FlowNetworkStopStations Business Logic Tier (BLT):

string flowNetworkName = "AT_LongLine";

string stationsToStop = "AT_LL_PumpStation1";

BLTParameterValueAccessor result;

BLTParameterValueAccessor message;

var bltClientFactory = new BLTClientFactory();

using (var client = bltClientFactory.Create("FlowNetworkStopStations"))

{

client.AddParameter(flowNetworkName);

client.AddParameter(stationsToStop);

client.AddParameter(out result); //Result is an out param

client.AddParameter(out message); // Message is an out param

client.Execute();

if (Int32.TryParse(result.Value.ToString(), out int r) && r != 0)

{

Console.WriteLine("FlowNetworkStopStations failed, error:" +

message.Value.ToString());

}

}

FlowNetworkStopStations Assembly Programming Example

You can reference the assembly bobjFlowNetworkStopStations.dll inside an application to invoke the Business Logic Tier (BLT) functionality directly.

The following is an example of how you can program using the FlowNetworkStopStations assembly inside an application.

Note: This application must be running on a RealTime server with AVEVA Pipeline Operations for Liquids installed.

string flowNetworkArgumentName = "model_name_in_database";

string stationsShutdownList = "station1 station2 station3";

var stationStopObject = new bobjFlowNetworkStopStations.bobjFlowNetworkStopStations();

try

{

      stationStopObject.Execute(flowNetworkArgumentName, stationsShutdownList);

}

catch(bobjFlowNetworkStopStations.Exceptions.FlowNetworkStopStationsProcessException ex)

{

      Console.WriteLine("Error code " + ex.Result + " " + ex.Message);

}