Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Pipeline Operations for Liquids

Weighted Average calculations for Accumulators

  • Last UpdatedApr 30, 2026
  • 3 minute read

Weighted Average (WA) values for accumulators reset on the top of hour.

To calculate a Weighted Average Meter Correction Factor (MCF), the system uses the Indicated Volume (IV) reported by the accumulator as a basis for the calculations. The following procedure is used:

Embedded Image (65% Scaling) (LIVE)

Embedded Image (65% Scaling) (LIVE)

Where Accumulator Previous IV is the indicated volume accumulated since top of hour not including the current processing cycle.

Embedded Image (65% Scaling) (LIVE)

To calculate a Weighted Average for Temperature (T), Pressure (P), Observed Density (OD), Flow Rate, Correction for Temperature of a Liquid (CTL), and the Correction for Pressure of a Liquid (CPL), the system uses the Gross Volume (GV) reported by the accumulator as a basis for the calculations. GV is the actual volume at flowing temperature and pressure after being corrected by the meter factor. The following procedure is used:

Embedded Image (65% Scaling) (LIVE)

Embedded Image (65% Scaling) (LIVE)

Embedded Image (65% Scaling) (LIVE)

Where Accumulator Previous GV is the gross volume accumulated since top of hour not including the current processing cycle.

Embedded Image (65% Scaling) (LIVE)

Where Y is one of the following: Temperature (T), Pressure (P), Observed Density (OD), Flow Rate, Correction for Temperature of a Liquid (CTL), or the Correction for Pressure of a Liquid (CPL).

To calculate a Weighted Average for Corrected Density (D), the system uses the Gross Standard Volume (GSV) reported by the accumulator as a basis for the calculations. The following procedure is used:

Accumulator Delta GSV = Accumulator Current GSV - Accumulator Previous GSV

Where Accumulator Previous GSV is the gross standard volume accumulated since Top of Hour (not including the current processing cycle).

Current WA of Corrected Density =

([(Current D value x Accumulator Delta GSV)+(Accumulator Previous GSV x Previous WA of D)])

(Accumulator Current GSV)

Where WA is Weighted Average and D is Corrected Density.