Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Pipeline Operations for Liquids

Understand the alarm/event messages to the message identifier for Action Sequences

Understand the alarm/event messages to the message identifier for Action Sequences

  • Last UpdatedApr 24, 2025
  • 4 minute read

The following table provides details for configuring the Action Sequence alarm/event messages.

Note: The messages noted in the table are designated as either alarms that generate identical events or simple events. In all cases, you can customize the message text and, where applicable, adjust the alarm severity. To update an alarm/event message, refer to the msgInfo table row for alarm/event message identifier of interest. For more information on configuration using the msgInfo table, refer to Volume 1 of the RealTime Administrator documentation.

Alarm/Event

Alarm/Event Message Configuration

Alarm Severity Configuration

Type

Action sequence <RECORD NAME> armed <USER AND SYSTEM NAME>.

ACTIONSEQ_ARMED

Base Message

Alarm & Event

Action sequence <RECORD NAME> does not have two-stage activation enabled. Ignoring Arm command <USER AND SYSTEM NAME>.

ACTIONSEQ_TWO_STAGE_NOT_ENABLED

N/A

Event

Action sequence <RECORD NAME> is <RECORD STATE>. Ignoring <COMMAND> command <USER AND SYSTEM NAME>.

ACTIONSEQ_IGNORE_COMMAND

N/A

Event

Action sequence <RECORD NAME> is already <RECORD STATE>. Ignoring <COMMAND> command <USER AND SYSTEM NAME>.

ACTIONSEQ_IGNORE_COMMAND_ALREADY

N/A

Event

Action sequence <RECORD NAME> started at step <STEP NAME> <USER AND SYSTEM NAME>.

ACTIONSEQ_STARTED_AT_STEP

N/A

Event

Action sequence <RECORD NAME> is already stopped. Ignoring Stop command <USER AND SYSTEM NAME>.

ACTIONSEQ_ALREADY_STOPPED

N/A

Event

Unable to start the action sequence at the specified step <STEP NAME> <USER AND SYSTEM NAME>. Step slot must be a valid point number greater than zero.

ACTIONSEQ_CANT_START_STEPSLOT_INVALID

N/A

Event

Action sequence <RECORD NAME> disarmed <USER AND SYSTEM NAME>.

ACTIONSEQ_DISARMED_COMMAND

Base Message

Alarm & Event

Action sequence <RECORD NAME> is not Armed. Ignoring Disarm command <USER AND SYSTEM NAME>.

ACTIONSEQ_IGNORE_DISARM_COMMAND

N/A

Event

Action sequence <RECORD NAME> pausing <USER AND SYSTEM NAME>.

ACTIONSEQ_PAUSE_COMMAND

N/A

Event

Action sequence <RECORD NAME> is not Executing. Ignoring Pause command <USER AND SYSTEM NAME>.

ACTIONSEQ_IGNORE_PAUSE_COMMAND

N/A

Event

Action sequence <RECORD NAME> resumed <USER AND SYSTEM NAME>.

ACTIONSEQ_RESUME_COMMAND

N/A

Event

Failed to resume action sequence <RECORD NAME> <USER AND SYSTEM NAME>. Could not find a valid step to resume.

ACTIONSEQ_RESUME_FAILED

Base Message

Alarm & Event

Action sequence <RECORD NAME> resumed at step <RESUMED STEP NAME> <USER AND SYSTEM NAME>.

ACTIONSEQ_RESUMED_AT_STEP

N/A

Event

Action sequence <RECORD NAME> is already running. Ignoring Resume command <USER AND SYSTEM NAME>.

ACTIONSEQ_ALREADY_RUNNING_IGNORE_RESUME

N/A

Event

Action sequence <RECORD NAME> is not Paused. Ignoring Resume command <USER AND SYSTEM NAME>.

ACTIONSEQ_NOT_PAUSED_IGNORE_RESUME

N/A

Event

Action sequence <RECORD NAME> is not armed, but received a Start command <USER AND SYSTEM NAME>. Bypassing arming stage and allowing execution to continue.

ACTIONSEQ_NOTARMED_START_REQUESTED

N/A

Event

Action sequence <RECORD NAME> is already Executing. Ignoring Start command <USER AND SYSTEM NAME>.

ACTIONSEQ_ALREADY_EXECUTING

N/A

Event

Failed to load action sequence <RECORD NAME>. Ignoring Start command <USER AND SYSTEM NAME>.

ACTIONSEQ_FAILED_TO_LOAD

Base Message

Alarm & Event

Failed to start action sequence <RECORD NAME> <USER AND SYSTEM NAME>. Could not find the specified step at which to start.

ACTIONSEQ_FAILED_TO_START

Base Message

Alarm & Event

Action sequence <RECORD NAME> started <USER AND SYSTEM NAME>.

ACTIONSEQ_STARTED

N/A

Event

Unable to start the action sequence at the specified step <STARTING STEP NAME> <USER AND SYSTEM NAME>. The target sequence step <STEP NAME> does not belong to the action sequence record.

ACTIONSEQ_CANT_START_TARGET_SEQ_STEP_INVALID

N/A

Event

Unable to start the action sequence at the specified step <STARTING STEP NAME> <USER AND SYSTEM NAME>. Could not find a sequence step record with that slot number.

ACTIONSEQ_CANT_START_STEP_RECORD_NOT_FOUND

Base Message

Alarm & Event

Stopping action sequence <RECORD NAME> <USER AND SYSTEM NAME>.

ACTIONSEQ_STOP

N/A

Event

Action sequence completed successfully.

ACTIONSEQ_COMPLETED_SUCCESSFUL

Base Message

Alarm & Event

Action sequence completed, however one or more steps failed.

ACTIONSEQ_COMPLETED_FAILED

Base Message

Alarm & Event

Action sequence failed to pause <USER AND SYSTEM NAME> at step <STEP NAME>. The executing step failed. Action sequence <RECORD NAME> is now stopped.

ACTIONSEQ_FAILED_TO_PAUSE

Base Message

Alarm & Event

Action sequence failed on step <STEP NAME>: <ERROR DESCRIPTION>.

ACTIONSEQ_FAILED_STEP

Base Message

Alarm & Event

Step <STEP NAME> failed: <ERROR DESCRIPTION>. Retry attempt <EXECUTION ATTEMPT> of <RETRY COUNT>.

ACTIONSEQ_STEP_FAILED_RETRY

N/A

Event

Sequence failed on step <STEP NAME>: ActionSequence <RECORD NAME> failed unexpectedly.

ACTIONSEQ_FAILED_STEP_UNEXPECTEDLY

Base Message

Alarm & Event

Step <STEP NAME> failed. Proceeding to failure step <STEP NAME>.

ACTIONSEQ_FAILED_STEP_BRANCH

Base Message

Alarm & Event

Step <STEP NAME> succeeded.

ACTIONSEQ_SUCCESSFUL_STEP

N/A

Event

Action sequence failed on step <STEP NAME>: Set point timed out.

ACTIONSEQ_FAILED_STEP_SETPOINT_TIMED_OUT

Base Message

Alarm & Event

Action sequence stopped <USER AND SYSTEM NAME> at step <STEP NAME>.

ACTIONSEQ_STOPPED

N/A

Event

Action sequence paused <USER AND SYSTEM NAME> at step <STEP NAME>.

ACTIONSEQ_PAUSED

N/A

Event

Sequence execution interrupted due to a fail-over or mode-switch.

ACTIONSEQ_INTERRUPTED

Base Message

Alarm & Event

Sequence execution interrupted at step <STEP NAME> due to a fail-over or mode-switch.

ACTIONSEQ_INTERRUPTED_WITH_STEP

Base Message

Alarm & Event

Step <STEP NAME> failed.No failure step exists for step. Terminating action sequence.

ACTIONSEQ_FAILED_NO_FAILURE_BRANCH

N/A

Event

Decision Step <STEP NAME> with a timeout of <TIMEOUT VALUE> second(s) has evaluated to false. Waiting for timeout to expire after an additional <TIME TO TIMEOUT VALUE> second(s) or a target result of true before proceeding.

ACTIONSEQ_DECSTEP_EVAL_FALSE_CONTINUE

N/A

Event

Decision Step <STEP NAME> has evaluated to true. If a step is linked to this result, it will be executed next.

ACTIONSEQ_DECSTEP_EVAL_TRUE

N/A

Event

Decision Step <STEP NAME> with a timeout of <TIMEOUT VALUE> second(s) has evaluated to false, and timeout has expired. If a step is linked to this result, it will be executed next.

ACTIONSEQ_DECSTEP_EVAL_FALSE_AFTER_WAIT

N/A

Event

Decision Step <STEP NAME> with a timeout of 0 second(s) has evaluated to false. Waiting indefinitely for the Decision Step to evaluate to true before proceeding.

ACTIONSEQ_DECSTEP_EVAL_FALSE_INDEFINITE

N/A

Event

Decision Step <STEP NAME> has evaluated to false. If a step is linked to this result, it will be executed next.

ACTIONSEQ_DECSTEP_EVAL_FALSE

N/A

Event

Decision Step <STEP NAME> with a timeout of <TIMEOUT VALUE> second(s) has evaluated to true. If a step is linked to this result, it will be executed next.

ACTIONSEQ_DECSTEP_EVAL_TRUE_AFTER_WAIT

N/A

Event

Executing legacy action sequence <NAME>. This action sequence should be upgraded. Please contact your administrator.

ACTIONSEQ_LEGACY

N/A

Event

Related Links