AVEVA Pipeline Operations for Liquids

NONE selection for the Temperature, Pressure, and Density Correction Tables

NONE selection for the Temperature, Pressure, and Density Correction Tables

  • Last UpdatedApr 24, 2025
  • 1 minute read

API1980

If NONE is selected for one of the following Correction Tables, the following will occur:

  • Temperature Correction Table: Temperature correction factor will default to one.

  • Pressure Correction Table: Pressure correction factor will default to one.

  • Density Correction Table: Observed density will be used as corrected density.

API2004

A selection of NONE for any correction table will result in a default table selected that is compatible with the other correction tables. For example, for the following configuration in the prodgroup table, the Temperature Correction Table will default to T6A:

  • Temperature Correction Table = NONE

  • Pressure Correction Table = API 11.2.1

  • Density Correction Table = T5A.

In This Topic