View Tank Information using the PLM Tank Summary window

View Tank Information using the PLM Tank Summary window

  • Last UpdatedApr 24, 2025
  • 2 minute read

To access the Pipeline Monitoring (PLM) Tank Summary window

  • Select Tank on the PLM Controls menu.

    The PLM Tank Summary window appears. Each meter type device assigned to the plm record is listed as a row, with device attributes in the columns.

    Embedded Image (65% Scaling) (LIVE)

The following table details the items on the PLM Tank Summary window

Column

Description

Vol Device Path

Reference to the measurement device.

Inh

If yes, this device is inhibited and measurements will not be used.

Auto Inh

This field specifies if the PLM Volume Device is automatically inhibited based on the state of a configured status, multistate, or Advanced Logic Processor (ALP) record.

Last Vol

Reading from the measurement device.

Leak Risk

If yes, device may be the source of a volume imbalance.

Leak risk is set if the last change in volume at the device exceeds the average change over the last 30 minutes by a certain factor. For more information, refer to AVEVA Pipeline Operations for Liquids Administrator documentation.

Name

The plmvoldevice table is used to contain data coming from the measurement devices. The Name field specifies the name of the plmvoldevice record that contains data coming from the measurement device referenced by the Vol Device Path.