AVEVA Pipeline Operations for Liquids

Weighted Average calculations for VFCs

  • Last UpdatedApr 30, 2026
  • 3 minute read

Weighted Average (WA) values for VFCs reset on the top of hour.

To calculate a Weighted Average Meter Correction Factor (MCF), the system uses the Indicated Volume (IV) reported by the child accumulators as a basis for the calculations. The following procedure is used:

Embedded Image (65% Scaling) (LIVE)

Embedded Image (65% Scaling) (LIVE)

Where VFC Previous IV is the indicated volume accumulated since top of hour not including the current processing cycle.

Embedded Image (65% Scaling) (LIVE)

To calculate a Weighted Average for Temperature (T), Pressure (P), Observed Density (OD), Correction for Temperature of a Liquid (CTL), and the Correction for Pressure of a Liquid (CPL), the system uses the Gross Volume (GV) as a basis for aggregating the weighted averages of the child accumulators. GV is the actual volume at flowing temperature and pressure after being corrected by the meter factor.

Embedded Image (65% Scaling) (LIVE)

Embedded Image (65% Scaling) (LIVE)

Where VFC Previous GV is the gross volume accumulated since top of hour not including the current processing cycle.

Embedded Image (65% Scaling) (LIVE)

Where Y is one of the following: Temperature (T), Pressure (P), Observed Density (OD), Correction for Temperature of a Liquid (CTL), or the Correction for Pressure of a Liquid (CPL).

To calculate a Weighted Average Sediment and Water Percent (S&W), the system uses the Gross Standard Volume (GSV) as a basis for the calculations. The following procedure is used:

Embedded Image (65% Scaling) (LIVE)

Embedded Image (65% Scaling) (LIVE)

Where VFC Previous GSV is the gross standard volume accumulated since top of hour not including the current processing cycle.

Embedded Image (65% Scaling) (LIVE)

To calculate a Weighted Average Flow Rate, the system uses the Gross Volume (GV) as a basis for the calculations. GV is the actual volume at flowing temperature and pressure after being corrected by the meter factor. The following procedure is used:

Embedded Image (65% Scaling) (LIVE)

Embedded Image (65% Scaling) (LIVE)

Where VFC Previous GV is the gross volume accumulated since top of hour not including the current processing cycle.

Embedded Image (65% Scaling) (LIVE)

To calculate a Weighted Average Corrected Density (D), the system uses the Gross Standard Volume (GSV) as a basis for aggregating the weighted averages of the child accumulators. The following procedure is used:

VFC Delta GSV = Sum of (Accumulator Delta GSV)

VFC Current GSV = VFC Delta GSV + VFC Previous GSV

Where VFC Previous GSV is the Gross Standard Volume accumulated since Top of Hour not including the current processing cycle.

Current WA of Corrected Density =

Sum(Accumulator WA of D x Accumulator GSV)

VFC Current GSV

Where D is Corrected Density.