Understand the Tank Ticket Device (TankTicketDevice) table
- Last UpdatedApr 24, 2025
- 4 minute read
The tank Ticket Device (tankTicketDevice) table of the AVEVA Pipeline Operations for Liquids database contains the following fields:
|
Internal Field |
Data Type |
Description (if detailed description required) |
|---|---|---|
|
msrepl_tran_version |
uniqueidentifier |
Unique record identifier. |
|
time |
GMTtime(int) |
This provides the time the ticket was created, using Greenwich Mean Time (GMT). |
|
offset |
GMToffset(smallint) |
GMT offset. |
|
ticketno |
varchar(15) |
Ticket number. |
|
nomId |
int |
|
|
batchXfer |
nameType(varchar32) |
The name of the batch transfer (batchXfer) record that generated the completed ticket. |
|
deviceName |
nameType(varchar32) |
|
|
ScountIV |
float |
Start of batch transfer Indicated Volume (IV). |
|
ecountIV |
float |
End of batch transfer IV. |
|
scountGSV |
float |
Start of batch transfer Gross Standard Volume (GSV). |
|
ecountGSV |
float |
End of batch transfer GSV. |
|
waod |
float |
Weighted Average Observed Density (WAOD). |
|
wad |
float |
Weighted Average Density (WAD). |
|
wat |
float |
Weighted Average Temperature (WAT). |
|
wap |
float |
Weighted Average Pressure (WAP). |
|
waf |
float |
Weighted Average Flow rate (WAF) over the time period of the ticket. |
|
wamcf |
float |
Weighted Average Meter correction factor (WAMCF). |
|
actobsdens |
float |
Actual telemetered observed density. |
|
actdens |
float |
Actual telemetered density. |
|
acttemp |
float |
Actual telemetered temperature. |
|
actpres |
float |
Actual telemetered pressure. |
|
actflow |
float |
Actual telemetered flow. |
|
mcf |
float |
Meter Correction Factor. |
|
ctl |
decimal (17,15) |
Weighted Average Volume Correction Factor for Temperature (CTL). |
|
cpl |
decimal(17,15) |
Weighted Average Volume Correction Factor for Temperature (CTL). |
|
ctpl |
float |
Combined Temperature and Pressure Correction factor (CTPL). |
|
expFlow |
float |
Expected pressure. |
|
expPres |
float |
Expected flow. |
|
IV |
float |
Gross uncalibrated volume. |
|
GV |
float |
Gross Volume (GV). |
|
GSV |
float |
Gross Standard Volume (GSV). |
|
origtemp |
float |
Original temperature before the manual override. |
|
origobsdens |
float |
Original observed density before the manual override. |
|
origdens |
float |
Original density before the manual override. |
|
origpres |
float |
Original pressure before the manual override. |
|
origflow |
float |
Original flow before the manual override. |
|
origctl |
float |
Original temperature correction factor before the manual override. |
|
origcpl |
float |
Original pressure correction factor before the manual override. |
|
origstartIV |
float |
Original starting IV. |
|
origstartGSV |
float |
Original starting GSV. |
|
origendIV |
float |
Original ending IV. |
|
origendGSV |
float |
Original ending GSV. |
|
faod |
char(1) |
Defines whether observed density is manually overridden. |
|
fad |
char(1) |
Defines whether density is manually overridden. |
|
fat |
char(1) |
Defines whether temperature is manually overridden. |
|
fap |
char(1) |
Defines whether the pressure is manually overridden. |
|
faf |
char(1) |
Defines whether the flow rate is manually overridden. |
|
fwaod |
char(1) |
Defines whether weighted average observed density is manually overridden. |
|
fwad |
char(1) |
Defines whether the weighted average density is manually overridden. |
|
fwat |
char(1) |
Defines whether the WAT is manually overridden. |
|
fwap |
char (1) |
Defines whether the WAP is manually overridden. |
|
fwaf |
char (1) |
Defines whether the WAF is manually overridden. |
|
fwamcf |
char(1) |
Defines whether weighted average meter correction factor is manually overridden. |
|
fstart |
char(1) |
Defines whether the start volume can be manually overridden. |
|
fend |
char(1) |
Defines whether the end volume can be manually overridden. |
|
fIV |
char(1) |
Gross uncalibrated volume. |
|
fGSV |
char (1) |
Net volume. |
|
usingVolCorr |
Char(1) |
This field specifies whether this revision was recalculated using the volume correction library when the Controller manually edited the completed ticket. |
|
Fmcf |
Char(1) |
This field specifies whether the MCF was overridden when the Controller manually edited the completed ticket. |
|
fctl |
Char(1) |
This field specifies whether the Volume Correction Factor for Temperature (CTL) was overridden when the Controller manually edited the completed ticket. |
|
fcpl |
Char(1) |
This field specifies whether the CPL was overridden when the Controller manually edited the completed ticket. |
|
fcptl |
Char(1) |
This field specifies whether the CTPL was overridden when the Controller manually edited the completed ticket. |
|
pressCorr |
char (1) |
Pressure correction. |
|
tempCorr |
char(1) |
Temperature correction. |
|
densCorr |
char (1) |
Density correction. |
|
startLevel |
varchar(15) |
Provides the starting level information. |
|
startLiqTemp |
float |
Provides the starting temperature of the product in the tank. |
|
startAmbTemp |
float |
Provides the starting temperature of the surrounding environment. |
|
startTempCorrFactor |
float |
The correction factor used on the starting temperature. |
|
startShellTempCorrFactor |
float |
|
|
startLiqDensity |
float |
The starting density of the product in the tank. |
|
startRoofSnowWeight |
float |
The starting weight of the snow on the roof of the tank. |
|
startRoofSnowLevel |
float |
The level of the snow on the roof of the tank at the beginning of the period of measurement. |
|
endLevel |
varchar(15) |
Provides the level of the product in the tank at the end of the period of measurement. |
|
endLiqTemp |
float |
Provides the temperature of the product in the tank at the end of the period of measurement. |
|
endAmbTemp |
float |
Provides the temperature of the surrounding environment at the end of the period of measurement. |
|
endTempCorrFactor |
float |
Provides the temperature correction factor used at the end of the period of measurement. |
|
endShellTempCorrFactor |
float |
|
|
endLiqDensity |
float |
Provides the density of the liquid at the end of the period of measurement. |
|
endRoofSnowWeight |
float |
Provides the weight of the snow on the roof at the end of the period of measurement. |
|
endRoofSnowLevel |
float |
Provides the level of the snow on the roof at the end of the period of measurement. |
|
volUnit |
varchar(15) |
Units in which the volume information is stored. |
|
densUnit |
varchar(15) |
Units in which the density information is stored. |
|
tempUnit |
varchar(15) |
Units in which the temperature information is stored. |
|
presUnit |
varchar(15) |
Units in which the pressure information is stored. |
|
audit_trail_revision |
int |
|
|
ownsysID |
tagIDtype(int) |
ID of the system to which the ticket belongs. |
|
datasetID |
tagIDtype(int) |
Dataset to which the ticket belongs. |
|
userName |
varchar(32) |
The name of the user that made the modification. |
|
revisionTime |
GMTtime(int) |
The time of the last revision. |
|
mass |
float |
This column provides the mass information. |
|
massUnit |