Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Pipeline Operations for Liquids

View information about a single Anomaly

  • Last UpdatedApr 24, 2025
  • 1 minute read

To display information about a single Anomaly

  • In the Anomaly Summary on the Pipeline Control window, select the row header of the desired record.

    The Anomaly Estimated Time of Arrival (ETA) window appears.

    All ETAs for the selected anomaly are shown.

The upper half of the Anomaly ETA window contains non-editable information about the selected anomaly. The colored rectangle in the top, left-hand corner indicates the anomaly type.

The following table details the items on the Anomaly ETA window.

Item

Description

Table and Field

Batch ID

Batch ID for the batch that the anomaly is in.

batch.id

Anomaly ID

Name of the anomaly.

anomaly.name

Slip Factor

Anomaly slip factor.

anomaly.sfact

Created

Time of anomaly creation.

anomaly.create_time

Anomaly Colour and Type

Provides the assigned color and type of anomaly.

anomaly.anm_type.anm_color

The Node ETAs summary in the lower half of the Anomaly ETA window shows the estimated time of arrival for the selected batch for each node that has ETA calculation enabled.

The following table details the Node ETAs section.

Item

Description

Table and Field

Name

Node name.

node.dispname

Time

ETA for anomaly at the node.

eta.time

GSV

Linepack volume from anomaly to the node.

eta.volume