Configuring the Pressure/Temperature Analogs Tab of the Pipe Segment Record
- Last UpdatedApr 24, 2025
- 2 minute read

The table defines the fields on the Pressure/Temperature Analogs tab and their corresponding Batch Tracking Compiler (BTC) attributes.
|
BTC Attributes |
Pressure/Temperature Analogs tab, pipe_segment Row Edit form |
Description |
|---|---|---|
|
PIPE |
Pipe Segment |
The pipe name. |
|
GROUP |
Group |
The group name. For more information about groups, see Configure the Batch Estimated Time of Arrival (ETA) tab of the Node record. |
|
Dataset |
Dataset defined by the pipeline record. This typically is not defined by a BTC attribute. |
|
|
SECT |
Section |
A logical grouping of pipe segments. |
|
UNITPROF |
Input Unit Profile |
The unit profile that the segment uses for display units and conversions. |
|
PRIDISPLAY |
Priority Display |
The easy eXtended Operator Station (ezXOS) display name that can be accessed from the Alarm Summary when this point generates an alarm. |
|
PIPEPRS |
Upstream Pressure
|
An upstream and downstream pressure analog may be configured with an optional auto-inhibit path. The point’s “Enable Inhibit” states, referenced by this inhibit path, must be mapped by way of State Configuration. |
|
PIPETMP |
Upstream Temperature
|