AVEVA Pipeline Operations for Liquids

Use the DRA Line Control dialog

  • Last UpdatedApr 24, 2025
  • 1 minute read

The Drag Reducing Agent (DRA) Line Control window is used to make changes to the DRALine record.

You can perform the following:

  • Change the current Flow Rate Range selection.

  • Set (or reset) the line to Automatic Mode.

    Embedded Image (65% Scaling) (LIVE)

The following table details the items on the DRA Line Control dialog.

Item

Description

Name

The name of the DRALine record.

Description

The description of the DRALine record.

Flow Rate Range

Displays the Flow Rates available for the Flow Rate Range category that has been configured for this DRALine record. The current assigned Flow Rate Range is highlighted as the dialog appears. If there is no currently assigned Flow Rate Range, then —none— is highlighted. You can change the Flow Rate Range by selecting a new one in this field.

Submit

Saves the changes to the Flow Rate Range.

Automatic Mode

Indicates if the DRALine record is in Automatic Mode (where DRA injectors on the line may automatically receive setpoint information via DRA Setpoint Lookup method).