Use the Tank Manual Overrides dialog
- Last UpdatedApr 24, 2025
- 3 minute read
Data is typically collected from the tank and entered directly into the RealTime database (RTDB) tank table. However, this process can be interrupted by placing a point into manual override mode.
When the device is in manual override mode, it will override values specified by the configuration (that is, telemetered point associated or an entry from the list selected) and is entered into the RTDB tank table.
Note: The value entered as manually overridden data has no effect on the output value or the state of the tank.
Use the Tank Manual Overrides dialog to override the temperature, tank level, snow load, or density of the tank.

The following table lists the action items and fields on the Tank Manual Overrides dialog.
|
Fields |
Description |
|---|---|
|
Tank Number |
The tank assigned number. |
|
Level Format |
This field indicates the level fraction format used to display all the Level values in the tank eXtended Operator Station (ezXOS) displays, alarm limits, and alarm messages. |
|
Current (Temperature) |
The current temperature in the tank. This is displayed in the units selected as part of the unit profile. |
|
Temperature: Manual Override, Override |
To use a manually entered temperature value:
|
|
Current (Tank Level) |
The current level in the tank. This level is converted to a gross volume using a volume conversion table (strapping table). |
|
Tank Level: Manual Override, Override |
To use a manually entered tank level value:
Note: The Tank Level needs to be entered as an uncorrected field level. |
|
Current (Snow Load) |
The current snow load weight in the tank. |
|
New Value (Snow Load) |
There is no telemetered value for the tank snow load. However, you can enter a snow load weight manually. To manually enter a snow load weight:
|
|
Current (Density) |
The current density in the tank. This is displayed in the units selected as part of the unit profile. |
|
Density: Manual Override, Override |
To use a manually entered, observed density value:
|
Note: Tank Level can only be controlled manually when they are configured by an Administrator to use a Direct Field Source in the Source Type and have a Remote Type of Level.