The following table details the elements involved in configuring the Drag Reducing Agent (DRA) Injector Setpoint Management Interface.

Element

RealTime Table Name

Description

DRA Injector

DRAInjector

The actual pump device that injects DRA into the pipeline as product is flowing by. An injector must belong to a DRA Injector Group to be included in DRA Injection Setpoint Management.

DRA Injector Group

DRAInjectorGroup

A grouping of DRA Injectors that indicates that the devices are co-located (that is, injecting into the same location on the pipeline). This grouping will ensure that only a single injector at that location is pumping at any given time. More specifically, it will verify that for a combination of inputs (DRA Product Group, DRA Flow Rate Range) only one injector in the group has a non-zero setpoint.

DRA Line

DRALine

The DRA Line is an abstract to a single whole or part of an actual pipeline. DRA Injection Setpoint Management is performed holistically from the viewpoint of the DRA Line.

Product Type

prodtype

The system-wide set of pipeline products that are being managed by the AVEVA Pipeline Operations for Liquids installation.