Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Pipeline Operations for Liquids

Tank level vs level increment

  • Last UpdatedApr 24, 2025
  • 1 minute read

The Tank Strapping API uses level increments to communicate level rather than a raw level string. This allows different formats of level to be represented by a single unit system. If you are currently using a display level, then this level will need to be converted to an increment system prior to being used in the Tank Strapping API.

For example:

  • If a strapping table is configured to use 16th inch, then a level reading of 005-03-03 would be converted to 1011 increments:

    (005 x 12 x 16) + (03 x 16) + 03 = 1011

  • If a strapping table configured as 100th meter, then a level reading of 5.5 would be converted to 550 increments:

    (5.5 x 100 ) = 550

For more information, refer to AVEVA Pipeline Operations for Liquids Administrator documentation.