View Linefill Type Device Information on the PLM Linefill Summary window
- Last UpdatedApr 24, 2025
- 2 minute read
To access the Pipeline Monitoring (PLM) Linefill Summary window
-
Select Linefill on the PLM Controls menu.
The PLM Linefill Summary window appears. Each Linefill type device assigned to the plm record is listed as a row, with device attributes in the columns.


The following table details the items on the PLM Linefill Summary window.
|
Columns |
Description |
|---|---|
|
Vol Device Path |
Reference to the measurement device. |
|
Inh |
If yes, this device is inhibited. Measurements are not used. A confirmation dialog is presented whenever this checkbox is selected to confirm that you intended to inhibit the device. |
|
Auto Inh |
This field specifies if the PLM Volume Device is automatically inhibited based on the state of a configured status, multistate, or Advanced Logic Processor (ALP) record. |
|
Last Vol |
Reading from the measurement device. |
|
Leak Risk |
If yes, device may be the source of a volume imbalance. Leak risk is set if the last change in volume at the device exceeds the average change over the last 30 minutes by a certain factor. For more information, refer to the AVEVA Pipeline Operations for Liquids Administrator documentation. |
|
Name |
The Plmvoldevice table is used to contain data coming from the measurement devices. Name refers to the name of the plmvoldevice record that contains data coming from the measurement device referenced by the Vol Device Path. |