Access the Anomaly Detect Control dialog
- Last UpdatedApr 24, 2025
- 2 minute read
Anomaly detectors are controlled through the Anomaly Detect Control dialog.
Controller changes to the adetect record can be done from this dialog.
To access the Anomaly Detect Control dialog
-
On the Anomaly Summary window, select the row header of the desired anomaly detector (adetect) record.
The Anomaly Detect Control dialog appears.

The following table details the items on the Anomaly Detect Control dialog.
|
Items |
Description |
Allowable Controller Edit |
Adetect Table Field |
|---|---|---|---|
|
Node |
Name of node where detector is located. |
No |
node |
|
Alarm |
The detect record alarm state can be in one of the following states. Normal Volume - Anomaly detected outside of the volume deadband for the detector location. Time - Anomaly detected early and outside the time deadband for estimated arrival time. Volume + Threshold - Anomaly detected early and outside of both volume deadband and time deadband. |
No |
almstate |
|
Early Detect Volume |
The volume deadband upstream from the anomaly location. If the anomaly location as predicted by Batch Tracking is in the deadband, the prediction is considered correct. |
Yes |
deadband_plus |
|
Late Detect Volume |
The volume deadband downstream from the anomaly location. If the anomaly location as predicted by Batch Tracking is in the deadband, the prediction is considered correct. |
Yes |
deadband_minus |
|
Early Detect Time |
Early arrival time deadband. If the anomaly is detected early and time of arrival estimated by Batch Tracking differs from the actual arrival time by an amount less than this deadband, the estimated time of arrival is considered correct. |
Yes |
t_deadband |
|
Monitoring Inhibited |
If checked, the adetect record is inhibited from processing. |
Yes |
inh |