Understand the items displayed on the Prover Control window
- Last UpdatedApr 24, 2025
- 5 minute read
The Meter Prover Control is designed to provide information at a glance about the meter that has been subject to proving. This section is designed to provide you with a brief description of each of the items on the Meter Prover Control window, so that you can better interpret the information.

Prover Data
The following table table describes the Prover Data available in the Meter Prover Control window.
|
Item |
Description |
|---|---|
|
Prover Name |
Name of the prover record. |
|
Base Volume |
This is the base volume of the prover in m3. This field holds a floating point number with four decimal places of accuracy. |
|
Prover Status |
The name of the status point to hold the status of the prover as indicated by the Programmable Logic Controller (PLC). The status of the prover as indicated by the PLC is either "busy" or "idle". |
|
Prover SW Status |
The Prover SW Status is an internal software status that the application maintains. The statuses available are:
|
|
Calc Method |
The calculation method in use by the prover. |
|
Prover Type |
Type of prover in use. |
|
Pipe Thickness |
The prover pipe thickness in mm. This field holds a floating point number with one decimal place of accuracy. |
|
Pipe Diameter |
The prover pipe diameter in mm. |
|
Seal |
If the status point is defined by your Administrator, proving will check for seal failure during the proving sequence. This field will indicate if there are any issues with the seal. |
|
EOR (End of Run) |
This field will indicate that the end of run has been achieved. |
Meter Data
The following table table describes the Meter Data available in the Meter Prover Control window.
|
Item |
Description |
|---|---|
|
Meter Name |
The name of the meter that is associated with the prover. |
|
K-factor |
This is the number of pulses per 0.1 m³ for this meter. This field holds an integer value. |
|
Max Count Deviation |
This is the maximum count deviation allowed for this meter. If the difference between the minimum and maximum pulse counts is greater than this value, you cannot accept the Meter Correction Factor (MCF) result. |
|
Current Count Deviation |
This field holds the absolute value of the difference between maximum and minimum number of counts for the four runs. If this value is greater than the allowable limit, the application marks the runs in violation by putting a (*) next to the count number for those runs. You cannot accept the MCF if this value is greater than the allowable limit. You must reprove the faulty runs, or complete an autoprove (prove 4 runs) to clear this situation. |
|
Max Repeatability % |
This field lists the maximum allowed deviation of prover run counts. |
|
Current Repeatability % |
This field lists the current value of the prover as it goes along. A run is marked as bad if the current repeatability % exceeds the maximum repeatability %. |
|
No. Runs to Prove |
Number of runs left to prove. |
User-entered information
The following table table describes the user-entered information in the Meter Prover Control window.
|
Item |
Description |
|---|---|
|
Batch ID |
Enter your Batch ID information. |
|
Tender ID |
Enter your Tender ID information. |
|
Product |
Enter your Product information. |
|
Density |
Enter your Density Information. |
|
Density Corr |
Enter your Density Correction information. |
|
HydroMtr Corr |
Enter your HydroMtr Corr information. |
Meter Proving commands
The following table table describes the Meter Proving commands available in the Meter Prover Control window.
|
Item |
Description |
|---|---|
|
Prove |
For more information, see Launching a Meter Prove run. |
|
Abort Prove |
For more information, see Abort a Meter Prove run. |
|
Clear Prove |
Select Clear Prove to clear the prove information. |
|
Accept |
For more information, see Accept a meter factor. |
|
Override Accept |
Select Override Accept to override any error messaging and accept the prove. For more information, see Accept a meter factor. |
Run information
The following table table describes the Run information available in the Meter Prover Control window.
|
Item |
Description |
|---|---|
|
Run Number |
Provides the run information for the meter prove. |
|
Temperature (ºC) |
Provides the temperature information associated with both the meter and the proving device. |
|
Pressure (PSI) |
Provides the pressure information associated with both the meter and proving device. |
|
CTS |
Correction factor for Temperature on Steel. |
|
CPS |
Correction factor for Pressure on Steel. |
|
CTL |
Correction factor for Temperature on Liquid. |
|
CPL |
Correction factor for Pressure on Liquid. |
|
Flow Rate (bbls/hr) |
Provides the flow rate information. |
|
Density |
Provides the density information. |
|
Count |
Proves the accumulator information. |
|
Meter Factor |
Supplies the Meter Factor that was applied to the run. |
|
Good Run? |
Provides an indication of whether the run was successfully executed. |
|
(Small Pvr) Det Temp |
The fields in this column list the temperature of the external detector in small volume provers. |
Report information
The following table table describes the Report information available in the Meter Prover Control window.
|
Item |
Description |
|---|---|
|
Report # |
Number of the report with which the meter prove is associated. |
|
Reports Completed |
Provides the number of reports that have been completed. |
|
Max Count Deviation Exceeded? |
This indicates whether the maximum count deviation has been exceeded. If it has been, the run will be considered bad. |
|
Ambient Temperature (ºC) |
The ambient temperature in degrees Celsius. This is supplied by an analog point. |
|
CTS Prover |
Correction factor for Temperature on Steel for the prover. |
|
CPS Prover |
Correction factor for Pressure on Steel for the prover. |
|
CTL Prover |
Correction factor for Temperature on Liquid for the prover. |
|
CPL Prover |
Correction factor for Pressure on Liquid for the prover. |
|
CTL Meter |
Correction factor for Temperature on Liquid for the Meter. |
|
CPL Meter |
Correction factor for Pressure on Liquid for the Meter. |
|
Runs Remaining |
How many meter proving runs that have yet to take place. |
|
Batch ID |
Enter the batch ID number. For non-batching meters, the Batch ID can consist solely of product or, optionally, can be in the same format as for batching meters (product-xxx). |
|
Product |
Product being transported by the meter. |
|
Coef. of Cubical Exp. |
The coefficient of cubical expansion (per °F) of the material of which the prover is made. |
|
Area Thermal Coef. |
This field lists the area thermal coefficient of expansion for the small volume prover chamber. |
|
Linear Thermal Coef. |
This field lists the linear thermal coefficient of expansion of the displacer shaft in small volume provers. |
|
Old Meter Factor |
This supplies the old meter factor. |
|
New Meter Factor |
This supplies the new meter factor. |
Prover run data
The following table table describes the Prover run data available in the Meter Prover Control window.
|
Item |
Description |
|---|---|
|
Run Number |
This field reports the number of the run. |
|
Temperature In / Out |
This field reports the incoming and outgoing temperatures reported by the proving process. |
|
Press In / Out |
This field reports the incoming and outgoing pressures reported by the proving process. |
|
Valid Reading T / P / D |
This field provides information on whether the temperature (T), pressure (P), and density (D) information supplied by the prover is valid. |