Configure the Drag Reducing Agent Injector Configuration (DRA Injector) Allowlist
- Last UpdatedJul 04, 2024
- 1 minute read
Note: For information on how to create a copy of the JSON file in the %DNADataRoot%\ADE\config\Settings directory, see Modify configuration settings.
-
In the %DNADataRoot%\ADE\config\Settings directory, open the copy of the DraInjectorTypesAllowList.json file.
-
Modify the file by adding or removing the tables and fields desired using the following format:
{
"LMS": {
"DraInjector": {
"FlowRateCalculationAllowListTables": [
{
"Name": "table1",
"Fields": [
"field1",
"field2",
...
"fieldx"
]
},
...
{
"Name": "table_xx",
"Fields": [
"field1",
"field2",
...
fieldxx
]
}
]
}
}
}
Notes: The LMS, DraInjector and FlowRateCalculationAllowListTables entries are required parameters that can not be changed.
You can add as many table entries to the allowlist as desired. Each table can have an unlimited number of items within the associated field. Each item entered for a field must exist, as named, in the associated table. If the field entered is mis-spelled or does not exist, the system ignores it.
All fields listed in this file must be of numeric type. If a non-numeric type is listed here and it is selected in the DRA Rate Management configurations, a configuration error alarm will be raised.
For more information on the RTDB table details, refer to Volume 1 of the AVEVA Enterprise SCADA RealTime Administrator Guide documentation. -
Save the file.