Understand the Flow Network Export Command Line tool parameters
- Last UpdatedApr 24, 2025
- 3 minute read
The following table describes the parameters available to use with the Flow Network Export Command Line tool.
|
Parameter |
Required or Optional |
Description |
|---|---|---|
|
-f (--file) |
Required |
The name of the .simx file created in AVEVA Process Simulation (APS). When uploaded to the RealTime database (RTDB), this will be the name of the Flow Network model. Notes: The .simx file must exist or an error will be generated. |
|
-e (--export) |
Optional |
The target RealTime system where the Flow Network will be uploaded. If the specified target RealTime system is not found when the export is started, an error message will be returned. |
|
-p (--project) |
Optional |
The AVEVA Pipeline Integrity Monitor (SimConstruct) project or workspace to use. Notes: If the parameter is set to a non-existing project/workspace, a new one with the specified
name will be created. |
|
-d (--dataset) |
Optional |
The name of the dataset the Flow Network should be attached to in the target RealTime system. Notes: The provided value will only be used if a new Flow Network is being loaded. In the
case of an update, this value will be ignored and the RealTime system will keep using
the previously assigned dataset. |
|
-c (--changeset) |
Optional |
The Management of Change (MoC) changeset to use. Notes: This parameter only applies to distributed systems. |
|
-u (--update) |
Optional |
This flag indicates to the tool to refresh the existing Flow Network model in the specified SimConstruct workspace using the .simx file before uploading the Flow Network model from the SimConstruct workspace into the RTDB. If this flag is not set, the tool will upload the Flow Network model from the specified SimConstruct workspace into the RTDB without refreshing the Flow Network model in the SimConstruct workspace using the .simx file. Note: If a project is not specified, this flag is irrelevant. |
|
-j (--json) |
Optional |
The folder path to export the generated .json file. Note: The generated file name format is "{PipelineName}_{MM-dd-yyyy-HH-mm}.json" |
|
-l (--logfile) |
Optional |
This sets the log file path. The path set can be absolute or relative. If it is not set, the log will be saved in C:\Users\<CurrentUser>\AppData\Local\AVEVA\SimSuite\log\FnetExport.log. Note: Ensure that you have permission to write files to the selected path. |
|
--verbose |
Optional |
This flag sets whether debug messages will be saved in the log file. If set, it will log the complete stack trace if an unexpected error happens and any debug log messages raised during the export. |
|
--silent |
Optional |
This flag will hide all log messages in the console output. |
|
--version |
Optional |
Displays the program version in use. Note: This parameter is exclusive and cannot be executed with any other parameter. |
|
--help |
Optional |
Displays Flow Network Export Command tool help. Notes: This parameter is exclusive and cannot be executed with any other parameter. |