Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Pipeline Operations for Liquids

Summary of validation and event messages for swapping tickets

Summary of validation and event messages for swapping tickets

  • Last UpdatedApr 24, 2025
  • 2 minute read

Message

Description

Cannot swap the active batch while the Batch Transfer is inhibited.

The Batch Swap failed because the Batch Transfer is currently inhibited.

The Batch Transfer Current Status must be NORMAL to swap the active batch.

The Batch Swap failed because the Batch Transfer Current Status field is something other than NORMAL. The Current Status field provides an indication of whether the record is NORMAL, ALARMING, STALE, STOPPED, or INHIBITED.

Cannot swap the active batch while the Batch Transfer is processing a Batch Switch on Manual Ticket Start.

Batch Switch on Manual Ticket Start is configured and the Batch Transfer is currently waiting for a field device reset.

Active ticket is not in Active state.

An Auto Switch or Switch on Volume possibly occurred while attempting to execute a Batch Swap and the ticket that was active when the Batch Swap was initiated is no longer the Active Ticket.

Pending ticket is not in Pending state.

An Auto Switch or Switch on Volume occurred while attempting to execute a Batch Swap, and the ticket that was pending when the Batch Swap was initiated is no longer a Pending Ticket.

Pending ticket must have a Scheduled GSV greater than zero.

The batch failed to swap because there was an invalid Scheduled GSV (Gross Standard Volume).

Pending ticket product type <ProductType> is not a recognized product type.

The batch failed to swap because the prodtype record is invalid.

Completed swap of Active Batch <Batch ID> - Ticket ID <Ticket ID> with Pending Batch <Batch ID> - Ticket ID < Ticket ID> as requested by <User> at <System>.

An event indicating the Batch Swap completed successfully.

Failed to swap Active Batch <Batch ID> - Ticket ID <Ticket ID> with Pending Batch <Batch ID> - Ticket ID < Ticket ID> as requested by <User> at <System>. <Reason>.

An event indicating the Batch Swap failed.

Batch swapping is not supported when a maintenance batch is involved.

Batch failed to swap because either the active batch or the pending batch is a maintenance batch.

Batch swapping is not supported when the active batch is changed from MAINTENANCE to NORMAL.

Batch failed to swap because the active batch was originally a maintenance batch, and then it was changed to normal by the Controller by selecting Maint to Normal.