The following table provides details for configuring the Advanced Logic Processor (ALP) application alarm/event messages.
Note: The following messages are all alarms that will generate an identical event. The message text can be customized and the alarm severity adjusted. To customize the configuration of an Alarm/Event Message, refer to the msgInfo table row for Alarm/Event Message Identifier of interest. For more information on configuration using the msgInfo table, refer to Volume 1 of the RealTime Administrator documentation.
|
Alarm/Event |
Alarm/Event Message Configuration |
Alarm Severity Configuration |
Type |
|---|---|---|---|
|
Advanced Logic Processor: <ALP Name> has invalid expression input types on row <Row Number>. Primary Input Path is <Primary Input Path Type> and Secondary Input Path is <Secondary Input Path Type>. Please contact your administrator. |
ALP_INVALID_INPUT_TYPES |
ALP_INVALID_INPUT_TYPES |
Alarm & Event |
|
Advanced Logic Processor: <ALP Name> has invalid expression input types on row <Row Number>. Primary Input Path type is <Primary Input Path Type> but Constant Value '<Constant Value>' is not <Type>. Please contact your administrator. |
ALP_INVALID_INPUT_AND_CONSTANT_TYPE |
ALP_INVALID_INPUT_AND_CONSTANT_TYPE |
Alarm & Event |
|
Advanced Logic Processor <ALP Name>: has unsupported type on InputPath <Input Type>. Please contact your administrator. |
ALP_UNSUPPORTED_INPUT_TYPE |
ALP_UNSUPPORTED_INPUT_TYPE |
Alarm & Event |
|
Advanced Logic Processor: <ALP Name> Input configuration has been updated and all expression inputs are valid. |
ALP_INPUT_CONFIG_UPDATED |
ALP_INPUT_CONFIG_UPDATED |
Alarm & Event |
|
Advanced Logic Processor: <ALP Name> has one or more invalid expression inputs. The input will automatically evaluate to true. Please contact your administrator. |
ALP_INVALID_EXPRESSION_INPUTS |
Base Message |
Alarm & Event |
|
Advanced Logic Processor <ALP NAME> expression evaluated to target: <ALP State> |
ALP_EXPRESSION_TARGET |
Base Message |
Alarm & Event |
|
Advanced Logic Processor <ALP Name> manually overridden to target: <ALP State> |
ALP_MANUALLY_TARGET |
Base Message |
Alarm & Event |
|
An unexpected error occurred during the evaluation of the ALP record. Please contact your system administrator. |
ALP_UNEXPECTED_EVALUATION |
Base Message |
Alarm & Event |
|
Failed to command the output point. Please contact your system administrator. |
ALP_FAILED_COMMAND_OUTPUT_POINT |
Base Message |
Alarm & Event |