Understand Product Injection Verification and Control alarms and events
- Last UpdatedApr 24, 2025
- 3 minute read
The following table provides details for configuring Product Injection Verification and Control alarm and event messages.
Note: The messages noted in the table are designated as either alarms that generate identical events or simple events. In all cases, you can customize the message text and, where applicable, adjust the alarm severity. To customize the configuration of an alarm/event message, refer to the msgInfo table row for alarm/event message identifier of interest. For more information on configuration using the msgInfo table, refer to Volume 1 of the RealTime Administrator documentation.
|
Alarm/Event |
Alarm/Event Message Configuration |
Alarm Severity Configuration |
Type |
|---|---|---|---|
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> entered the injection zone of the compatible batch. An ON command will not be sent to <TABLE NAME (STATUS/MULTISTATE)> due to a Control Delay (configured at <CONTROL DELAY CONFIGURTION> minutes). The next command can be sent after <REMAINING CONTROL DELAY TIME> minutes. |
PIV_AUTO_ON_COMMAND_CONTROL_DELAY |
N/A |
Event |
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> exited the injection zone of the compatible batch. An OFF command will not be sent to <TABLE NAME (STATUS/MULTISTATE)> due to a Control Delay (configured at <CONTROL DELAY CONFIGURTION> minutes). The next command can be sent after <REMAINING CONTROL DELAY TIME> minutes. |
PIV_AUTO_OFF_COMMAND_CONTROL_DELAY |
N/A |
Event |
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> will reach the end of the downstream no injection zone of the compatible batch (configured at <DOWNSTREAM ZONE CONFIGURATION>) and issue an ON command in approximately <DOWNSTREAM REMAINING WARNING ZONE VOLUME (Calculated)>. |
PIV_DOWNSTREAM_WARNING_VOLUME |
N/A |
Event |
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> will reach the upstream no injection zone of the compatible batch (configured at <UPSTREAM ZONE CONFIGURATION>) and issue an OFF command in approximately <UPSTREAM REMAINING WARNING ZONE Volume (Calculated)>. |
PIV_UPSTREAM_WARNING_VOLUME |
N/A |
Event |
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> will reach the end of the downstream no injection zone of the compatible batch (configured at <DOWNSTREAM ZONE CONFIGURATION>) and issue an ON command in approximately <DOWNSTREAM REMAINING WARNING ZONE TIME (Calculated)> - at an effective flow rate of <SEGMENT FLOW RATE>. |
PIV_DOWNSTREAM_WARNING_TIME |
N/A |
Event |
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> will reach the upstream no injection zone of the compatible batch (configured at < UPSTREAM ZONE CONFIGURATION>) and issue an OFF command in approximately <UPSTREAM REMAINING WARNING ZONE TIME (Calculated)> - at an effective flow rate of <SEGMENT FLOW RATE>. |
PIV_UPSTREAM_WARNING_TIME |
N/A |
Event |
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> is out of the upstream warning zone. |
PIV_FLUCTUATING_AROUND_UPSTREAM_WARNING_ZONE |
N/A |
Event |
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> is out of the downstream warning zone. |
PIV_FLUCTUATING_AROUND_DOWNSTREAM_WARNING_ZONE |
N/A |
Event |
|
Automatic Product Injection and Verification Control has been disabled for pipeline <PIPELINE NAME> by <USER> at <LOCATION> due to deactivating the pipeline | system startup. |
PPL_EVENT_DISABLE_PRODUCT_INJECTION |
N/A |
Event |
|
Automatic Product Injection and Verification Control has been re-enabled for pipeline <PIPELINE NAME> by <USER> at <LOCATION>. |
PPL_EVENT_ENABLE_PRODUCT_INJECTION |
N/A |
Event |
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> entered the injection zone of the compatible batch. Sending an ON command to <TABLE NAME (STATUS/MULTISTATE)> <POINT NAME> point. |
PIV_AUTO_ON_COMMAND |
PIV_AUTO_ON_COMMAND |
Alarm & Event |
|
Product Transfer Checking Record <FLOW TRANSFER NAME>: Node <NODE NAME> exited the injection zone of the compatible batch. Sending an OFF command to <TABLE NAME (STATUS/MULTISTATE)> <POINT NAME> point. |
PIV_AUTO_OFF_COMMAND |
PIV_AUTO_OFF_COMMAND |
Alarm & Event |
|
One or more errors occurred in Product Injection BLT on FlowTransfer <FLOW TRANSFER NAME>. Please check the log file for more details. |
PIV_GENERIC_ALARM |
PIV_GENERIC_ALARM |
Alarm & Event |
|
The Flow Transfer Record <FLOW TRANSFER NAME> has configuration errors, due to an incorrect reference. See error logs for more details and contact your system administrator. |
PIV_CONFIGURATION_ALARM |
PIV_CONFIGURATION_ALARM |
Alarm & Event |
|
The Flow Transfer Record <FLOW TRANSFER NAME> configuration error has been resolved. |
PIV_CONFIGURATION_RTN |
PIV_CONFIGURATION_RTN |
Alarm & Event |