To view more details about the device sources

  • Select the row header of the device source associated with the Batch Transfer that you would like to view the Batch Transfer Source Summary window.

    The Batch Transfer Source window appears.

The following table lists the fields on the Batch Transfer Source dialog:

Group Type

Fields

Description

Batch Transfer Source

Source Name

The name of this source record.

Device Path

Provides the pathway to the device where the record gathers its source information.

Type

The type of source in use by the batchXferSource record. Currently there are Rate, Tank, Virtual Flow Computer, and Flow Computer sources, though a plugin can be created for any source that provides a volume reading.

Auto Inh Allowed

If selected, Auto Inhibit is enabled for this source, meaning that if an Auto Inhibit point is configured, when that point changes to a state configured in Advanced Database Editor (ADE), this source (and all its devices) will be inhibited, and vice versa.

Auto Inhibit Point

A path to either a status or multistate point that controls Auto Inhibit. For it to be used, Auto Inh Allowed must read Yes.

Auto Inhibited

Will read Yes if the point is currently being inhibited by a configured Auto Inhibit point.

Inhibit Record

If selected, the source will immediately be inhibited, along with all of the associated devices.

Batch Transfer Source Calculation Records

Device ID

The configured device identifier. Typically, this is the name of the accumulator connected to the source the device is associated with.

GSV

The Gross Standard Volume (GSV) the device has recorded.

GSflow

The current flow rate on the device corrected to standard temperature and pressure.

Mass

The current mass on the device.