Configure the Monitoring tab of the FcConfigTelemetered Row Edit dialog
- Last UpdatedApr 24, 2025
- 2 minute read
This tab is used to configure the monitoring of the signals from the Flow Computer. In this instance, the Flow Computer is tasked with issuing the Batch Start, Batch Split and Batch Stop commands, and the information collected by the Monitoring tab is purely informational: the Flow Computer is reporting back on activities performed and an event is generated based on signals received.

Items on the fcConfigTelemetered Row Edit: Monitoring Tab
|
Item |
Description |
|---|---|
|
Batch Start Indicator Path |
Click (...) to select the pathway to a status or multistate point that will provide indication that the batch has started. After selecting (...), the Path Selector appears. Select a table and record. Until a table and record are selected, you will not be able to select Accept. For more information about how to select a pathway, refer to Volume 1 of the RealTime Administrator documentation. |
|
Batch Start Indicator Criteria |
Click (...) to open the Status or Multistate Message Selector. This allows you to define the message that will indicate to the system that a batch start has occurred. |
|
Batch Split Indicator Path |
Click (...) to select the pathway to a status or multistate point that will provide indication that the batch has split. After selecting (...), the Path Selector appears. Select a table and record. Until a table and record are selected, you will not be able to select Accept. For more information about how to select a pathway, refer to Volume 1 of the RealTime Administrator documentation. |
|
Batch Split Indicator Criteria |
Click (...) to open the Status or Multistate Message Selector. This will allow you to define the message that will indicate to the system that a batch split has occurred. |
|
Batch Stop Indication Path |
Click (...) to select the pathway to a status or multistate point that will provide an indication that the batch has stopped. After selecting (...), the Path Selector appears. Select a table and record. Until a table and record are selected, you will not be able to select Accept. For more information about how to select a pathway, refer to Volume 1 of the RealTime Administrator documentation. |
|
Batch Stop Indicator Criteria |
Click (...) to open the Status or Multistate Message Selector. This will allow you to define the message that will indicate to the system that a batch stop has occurred. |