Summary of messages and alarms
- Last UpdatedApr 24, 2025
- 6 minute read
|
Message |
Description |
|---|---|
|
The validation passed for a new DRA line configuration on DRA line: '{DRALINE_NAME}'. |
Issued when a new set of configuration for Setpoint Lookup has passed validation. No action is required. |
|
Current flowrate '{CURRENT_FLOW}' at DRA location is less than minimum flowrate '{MINIMUM_FLOW}'. |
Issued when the flow rate summation of all the rates flowing past the Injector is less than the Administrator-configured minimum threshold. |
|
Violation state '{VIOLATION_STATE}' detected by violation detector. |
Issued when the status or multistate configured for additional violation checking enters an Administrator-configured violation state. |
|
The validation for the DRA configuration of the DRA line: '{DRALINE_NAME}' was not successful. Please see the error log for details. |
Issued when a new set of configuration for Setpoint Lookup has not passed validation. The system error logs should be consulted to determine and correct the errors before attempting to load the new configuration again. |
|
DRA is enabled by {username}. |
A return to normal alarm generated when the Drag Reducing Agent (DRA) injector is re-enabled by an Administrator or Controller. |
|
DRA is disabled by {username}. |
Alarm generated when the Drag Reducing Agent (DRA) Injector is disabled by an Administrator or Controller. |
|
Density is within density range of prohibited products: {LIST_OF_PRODUCTS}. |
Issued when the densitometer detects a density that is within a the max/min density range of a known DRA-incompatible product. |
|
DRA Injection point '{INJECTOR_NAME}' automatically sending command '{SHUTDOWN_COMMAND}'. |
Issued when Automatic DRA Shutdown is enabled and a violation is detected. Usually accompanied by another alarm describing the violation. |
|
DRA violation conditions are cleared. DRA is allowed to be started. |
Issued when all violation conditions have cleared for an injector that was previously in violation. |
|
Startup DRA Injection Failure:{failure message}. |
Issued when an attempt to start up the DRA Injection point has failed. |
|
Shutdown DRA Injection Failure:{failure message}. |
Issued when an attempt to shut down the DRA Injection point has failed. |
|
DRA Injection point {currentDraInjector.Underlying Point.PointName} shutdown failure is cleared. |
A return to normal alarm generated when the shutdown failure is cleared. |
|
DRA Injection Point '{PointName}' shutdown failure after three attempts. |
If your Administrator has enabled the DRA Automatic Shutdown feature, three attempts to shut down the DRA Injection point will be made. After three unsuccessful attempts at shutting the injector down, this alarm will be issued. |
|
DRA Injection point '{INJECTOR_NAME}' automatically sending command '{STARTUP_COMMAND}'. |
Issued when the DRA Injector is in Automatic mode and an attempt has been made to start up the DRA pump based on operational conditions. |
|
DRA Injection Point '{PointName}' startup failure after three attempts. |
Issued when the DRA Injector has enabled Automatic mode. After three unsuccessful attempts at starting the injector, this alarm is issued. |
|
DRA rate issued to analog point by setpoint command unsuccessful. View log for details. |
The DRA Injector application attempted to send a setpoint to an analog point, and the command failed. The reason for the failure is in the error logs for the system. Please contact your Administrator. |
|
DRA rate '0' is issued to analog point '{ANALOG}' by setpoint command. |
The DRA reset event that is generated when the DRA Injection Analog point is reset to zero by setpoint command. |
|
DRA rate setpoint command was not issued due to the update frequency period. |
The DRA error event that is generated when the update frequency has passed while trying to update the DRA Injection Rate Analog point directly. |
|
DRA rate '{DRA RATE}' is issued to analog point '{ANALOG}' by setpoint command. |
The DRA set event that is generated when the DRA Injection Rate Analog point is set directly by a value. |
|
Automatic Mode enabled. |
Issued when you enable the automatic mode of a DRA Line or a DRA Group. |
|
Automatic Mode disabled. |
Issued when you disable the automatic mode of a DRA Line or a DRA Group. |
|
Target flow rate set to โ{FLOWRATE}โ. |
Issued when you modify the target flow rate group for a DRA Line or a DRA Group. |
|
An invalid DRA line configuration was encountered during RealTime validation. Please see the error log for details. |
Issued when the existing configuration for Setpoint Lookup has not passed validation. Consult the system error logs and correct the errors to make Setpoint Lookup functional again. |
|
The new DRA configuration for the DRA line: '{DRA LINE}' has changed the flow rate ranges. Please select a new flow rate range for each DRA line or group. |
Issued when the new configuration for Setpoint Lookup has caused the flow rate range selection to reset. The Controller must select a new flow rate range for each DRA line or group before Setpoint Lookup will resume evaluating. |
|
DRA incompatible products '{product name}' found in Upstream Zone. |
Alarm generated when there is an incompatible product violation in the upstream zone.
|
|
DRA rate setpoint command was not issued due to the update frequency. |
An event is issued when a Drag Reducing Agent (DRA) Injector passed the configured
setpoint Period time limit. |
|
DRA rate '{rate value}' is issued to analog point '{analog name}' by setpoint command. |
The Drag Reducing Agent (DRA) Injector application sends a setpoint to an analog point, and the command is successful and the system logs an event. |
|
Product compatibility violation between Tank '{TANK}' and Batch transfer '{BATCH TRANSFER}' (Products {VIOLATING PRODUCTS}). |
Alarm generated when there is a violation with tank product flowing into a Batch Transfer. |
|
Product compatibility violation between Tank '{TANK}' and VFC '{VIRTUAL FLOW COMPUTER}' (Products {VIOLATING PRODUCTS}). |
Alarm generated when there is a violation with Tank flowing into a VFC. |
|
Product compatibility violation between DRA Injection and Pipeline {PIPELINE} (Product {VIOLATING PRODUCTS} incompatible). |
The DRA violation alarm that is generated when there is a violation with the pipeline. |
|
Product compatibility violation between DRA Injection and Batch transfer {BATCH TRANSFER} (Product {VIOLATING PRODUCTS} incompatible). |
The DRA violation alarm that is generated when there is a violation with the batch transfer. |
|
Product compatibility violation between Pipeline {PIPELINE} and Batch transfer {BATCH TRANSFER} (Products {VIOLATING PRODUCTS}). |
The DRA violation alarm that is generated when there is a violation between the pipeline and batch transfer. |
|
Product compatibility violation between Pipeline {PIPELINE} and VFC {VIRTUAL FLOW COMPUTER} (Products {VIOLATING PRODUCTS}). |
The DRA violation alarm that is generated when there is a violation between the pipeline and VFC. |
|
Product compatibility violation between BatchXfer {BATCH TRANSFER} and Pipeline {PIPELINE} (Products {VIOLATING PRODUCTS}). |
The DRA violation alarm that is generated when there is a violation between the Batch Transfer and the pipeline. |
|
Product compatibility violation between Batch transfer {BATCH TRANSFER} and Tank {TANK} (Products {VIOLATING PRODUCTS}). |
The DRA violation alarm that is generated when there is a violation between the Batch Transfer and Tank. |
|
Product compatibility violation between VFC {VIRTUAL FLOW COMPUTER} and Tank {TANK} (Products {VIOLATING PRODUCTS}). |
The DRA violation alarm that is generated when there is a violation between the VFC and Tank. |
|
Product incompatibility resolved between {OBJECT 1} and {OBJECT 2}. |
The alarm generated when the product incompatibility is resolved. |
|
Product compatibility violation between VFC '{VIRTUAL FLOW COMPUTER} and Pipeline '{PIPELINE}' (Products {VIOLATING PRODUCTS}). |
Alarm generated when there is a violation between the VFC and Pipeline.
|
|
Product compatibility violation between DRA Injection and VFC '{VIRTUAL FLOW COMPUTER}' (Product '{VIOLATING PRODUCTS}' incompatible). |
Alarm generated when there is a violation with a between the VFC and DRA injector.
|
|
Exception thrown: {EXCEPTION MESSAGE}. |
The DRA exception event that is generated when an exception is thrown while trying to send the set point command. |
|
DRA product group set to '{PRODUCT GROUP NAME}'. |
The DRA set event that is generated when the DRA product group of the DRA injector group is set. |
|
DRA flow rate range set to '{0}'. |
The DRA set event that is generated when the DRA flow rate range of the DRA injector group is set. |
|
Target Concentration is set to 0 PPM. |
Issued when the DRA injector's concentration is set to 0. |
|
The DRA Flow Rate sources for this injector are using deprecated configuration fields. They need to be updated to use the full path. See error logs for more details and contact the system administrator. |
Issued when a DRAInjector is configured to use DRARate.flowRate.point instead of DRARate.flowRate.path for a flow rate when the Rate Management Method is calculated. |
|
Configuration error due to an invalid DRA Flow Rate source for this injector. See error logs for more details and contact the system administrator. |
Issued when a DRAInjector is configured to use a flow rate path that does not point to a valid numeric field when the Rate Management Method is calculated. |
|
Configuration error has been resolved. |
Issued when the flow rate for calculation configuration issues have been resolved. |