AVEVA Pipeline Operations for Liquids

Use the DRA Control window to make changes to the DRA Records

Use the DRA Control window to make changes to the DRA Records

  • Last UpdatedApr 24, 2025
  • 2 minute read

The DRA Injector Control window is used to make minor operational changes to the DRA records.

Your Administrator has the ability to inhibit the control that you have over the following settings:

  • Entering a value for the DRA Concentration

  • Inhibiting the monitoring of Product Transfer Checking (Inhibit Violation Check)

  • Disabling the Injector (Disable Injector)

The permissions for each of these features are assigned separately, so depending on the nature of your responsibilities, you may be able to enter a value for the DRA Concentration, but not be able to Disable Injector.

Item

Description

State

The DRAInjector record can be in the following states:

  • Unknown

  • Running

  • Stopped

  • Violation-Running

  • Violation-Stopped

  • Violation-Unknown

DRA Fluid Type

Indicates whether the DRA injector is expected to use light or heavy DRA fluid.

Rate Management Method

Displays whether the rate is not managed (None), Calculated, or determined by Setpoint Lookup.

DRA Concentration (ppm)

Type an appropriate value for DRA concentration. If your Administrator has enabled the functionality, it is possible to type a value between 1 and 1,000,000 parts per million (ppm).

Inhibit Violation Check

Inhibits the violation checking of the DRAInjector record. If selected, the DRAInjector record will not be monitored for potentially problematic conditions. If the Administrator has inhibited the monitoring of violation checking, you will not be able to inhibit the violation check until you are given the permission to do so by the Administrator. Inhibiting the violation check also bypasses the Rules Validation Engine (RVE) rule checking.

Disable Injector

Disables the injector. If you select this checkbox, you are prevented from starting the injector. If selected by the Administrator, you will be prevented from enabling the injector.

Injector

Opens the Status/Multistate/Pump Control dialogs. If the injector is enabled, it will be possible to use the Status/Multistate/Pump Control dialogs to inject DRA. If the injector has been disabled, and the status, multistate, or pump point is started or stopped, an error message will appear to indicate that the injector has been disabled, either by you or the Administrator.

Batch Transfer(s)

Opens a small summary showing the Batch Transfers configured to provide product to this injector.

Flush Point

Opens a screen detailing the DRA Injector Flush Point.

Event Summary

Opens the Event Summary. For more information about the Event Summary, refer to the AVEVA Enterprise SCADA HMI Controller documentation.

Alarm Summary

Opens the Alarm Summary. For more information about the Alarm Summary, refer to the AVEVA Enterprise SCADA HMI Controller documentation

Priority Display

If configured, the Priority Display allows you to quickly open a window of your choice. For more information about the Priority Display, refer to the AVEVA Enterprise SCADA HMI Controller documentation