AVEVA Pipeline Operations for Liquids

AVEVA Pipeline Operations for Liquids 2025 Patch 2 release notes

AVEVA Pipeline Operations for Liquids 2025 Patch 2 release notes

  • Last UpdatedOct 13, 2026
  • 7 minute read

Note: When you copy a file over from a network share or computer, you may need to unblock the file. After copying a file to its destination, right-click on the file and select Properties. In the Security section on the General tab, ensure that Unblock is selected.

The AVEVA Pipeline Operations for Liquids 2025 Patch 2 release is focused on reliability and stability. This update rolls up the hotfixes released since the AVEVA Pipeline Operations for Liquids 2025 Patch 1 release into a single, streamlined version for easier deployment and support.

The AVEVA Pipeline Operations for Liquids 2025 Patch 2 release notes describe the software, installation steps, and the fixed issues and changes that we have made since the AVEVA Pipeline Operations for Liquids 2025 Patch 1 release.

Note: As standard practice, projects and customers should make sure to install the latest patches for these product versions.

Note: This release is compatible with JSON serialization.

Prerequisite software

Before installing AVEVA Pipeline Operations for Liquids 2025 Patch 2, ensure that the following is already installed on the system:

  • AVEVA Pipeline Operations for Liquids 2025 Patch 1

Microsoft Installer (MSI)

  • Software Prerequisite MSI File(s)

    To ensure a fully operational and supported system, the previously released product components (and all contents) for AVEVA Pipeline Operations for Liquids 2025 Patch 1 must be installed from the associated MSI file(s) prior to applying this patch.

    Notes: The MSI version numbers should match the versions listed in the table; however, version numbers may be higher if you have hotfixes installed.

    For more information on previously released patches, refer to the applicable set of release notes. If you do not have access to the release notes, contact the AVEVA Knowledge & Support Center.

    Product Component
    (Microsoft Windows Program Name)

    MSI File name

    MSI Version

    Release version

    AVEVA Enterprise SCADA ADE Client

    ADE.Client.msi

    10.4.0.504

    AVEVA Enterprise SCADA 2025 Patch 1

    AVEVA Enterprise SCADA Historical Datapump

    Historical.datapump.msi

    10.4.0.493

    AVEVA Enterprise SCADA RealTime ADE

    RealTime.ADE.msi

    10.4.0.174

    AVEVA Enterprise SCADA RealTime Displays

    RealTime.ezXOS.msi

    10.4.0.271

    AVEVA Enterprise SCADA RealTime Service

    RealTime.service.msi

    10.4.0.1986

    AVEVA Enterprise SCADA Applications VirtualRTU Player

    Applications.VirtualRTU.Player.msi

    10.4.0.323

    AVEVA Enterprise SCADA OPC DA Server

    OPC.DAServer.msi

    10.4.0.841

    AVEVA Enterprise SCADA SystemServices Common

    SystemServices.Common.msi

    10.4.0.722

    AVEVA Pipeline Operations for Liquids ADE

    LMS.ADE.msi

    10.4.0.1226

    AVEVA Pipeline Operations for Liquids RealTime

    LMS.RealTime.msi

    10.4.0.3484

    AVEVA Pipeline Operations for Liquids Displays

    LMS.ezXOS.msi

    10.4.0.410

    AVEVA Enterprise SCADA Historical Displays

    Historical.ezXOS.msi

    10.4.0.148

    AVEVA Enterprise SCADA 2025

    AVEVA Enterprise SCADA Management of Change Orchestrator

    ManagementOfChange.Orchestrator.msi

    10.4.0.464

  • Software Patch MSI File(s) Included in this Release

    Product Component
    (Microsoft Windows Program Name)

    MSI File name

    MSI Version

    Release version

    AVEVA Enterprise SCADA ADE Client

    ADE.Client.msi

    10.4.0.519

    AVEVA Enterprise SCADA 2025 Patch 2

    AVEVA Enterprise SCADA Historical Datapump

    Historical.datapump.msi

    10.4.0.506

    AVEVA Enterprise SCADA RealTime ADE

    RealTime.ADE.msi

    10.4.0.186

    AVEVA Enterprise SCADA RealTime Displays

    RealTime.ezXOS.msi

    10.4.0.276

    AVEVA Enterprise SCADA RealTime Service

    RealTime.service.msi

    10.4.0.2025

    AVEVA Enterprise SCADA Applications VirtualRTU Player

    Applications.VirtualRTU.Player.msi

    10.4.0.341

    AVEVA Enterprise SCADA OPC DA Server

    OPC.DAServer.msi

    10.4.0.851

    AVEVA Enterprise SCADA SystemServices Common

    SystemServices.Common.msi

    10.4.0.731

    AVEVA Enterprise SCADA Historical Displays

    Historical.ezXOS.msi

    10.4.0.172

    AVEVA Enterprise SCADA Management of Change Orchestrator

    ManagementOfChange.Orchestrator.msi

    10.4.0.486

    AVEVA Pipeline Operations for Liquids ADE

    LMS.ADE.msi

    10.4.0.1246

    AVEVA Pipeline Operations for Liquids RealTime

    LMS.RealTime.msi

    10.4.0.3527

    AVEVA Pipeline Operations for Liquids Displays

    LMS.ezXOS.msi

    10.4.0.429

    Pre-installation configuration

There are no pre-installation configuration requirements for this release.

Installation

To install AVEVA Pipeline Operations for Liquids 2025 Patch 2

  1. Sign in to the computer as a member of DNA Installers.

  2. Shut down all AVEVA Enterprise SCADA services.

  3. Copy the 2025 Patch 2 MSI files to an accessible location on any computer running the MSI files listed under Software Patch MSI File(s) in Prerequisite software.

  4. Run the individual 2025 Patch 2 MSI files.

  5. Apply the post-installation configuration procedures

Post-installation configuration

Update ezXOS elements in the data root

The following procedure details how to update easy eXtended Operator Station (ezXOS) elements in the data directory (that is, %DNADataRoot%) on either the display source or the Display Edit Station (DES).

  1. Sign in as a member of DNA Installers.

  2. On the desktop, right-click the Windows PowerShell for DNA shortcut, and then select Run as administrator.

    Windows PowerShell for DNA opens.

  3. Run the following commands:

    Set-silo ezxos

    pdt -fo CNTL_TANK_LIMITS.XEM

    pdt -fo CNTL_TANK_CONTROL.XEM

    pdt -fo CNTL_TANK.XEM

    Note: Updated XEM files are located in the %DNAInstallRoot%\Shared\elements\displays\lms directory.

    Update ADE changes

    After installing the Advanced Database Editor (ADE) MSI versions, proceed as follows:

    1. On the desktop, right-click the Windows PowerShell for DNA shortcut, and then select Run as administrator.

      Windows PowerShell for DNA opens.

    2. Run the following commands:

      Set-silo ADE

      DBEditDisplayschemaMerge.exe -f Schema

      Fixed issues

      The following issues were fixed.

      ID

      Description

      Case–960666007

      (Defect–4960215 and 4286540)

      This defect fix addresses an issue where an Administrator was unable to create a Batch Transfer or a Tank record on a non-owning system even if it had configuration privileges.

      Case–962672253

      (Defect–4417987)

      This defect fix addresses an issue where cloning an existing Product Type record in Advanced Database Editor (ADE) to create a new one did not include the Andrade correlation factors, which caused hydraulic profile calculations to report NaN errors (that is, not a number) for dynamic viscosity.

      Case–962719599

      (Defect–4566685)

      This defect fix addresses an issue where reversing the flow direction of a pipeline could cause previously completed batches to be reinserted into the Batch Tracking model.

      Case–962819245

      (Defect–4773747)

      This defect fix addresses an issue where Batch Transfer calculations did not perform the required unit conversion on the density reading if the underlying source was set to a rate point.

      Case–962823757

      (Defect–4773736)

      This defect fix addresses an issue where an unhandled exception was thrown when right-clicking was performed on the top-left cell of the Strapping Elements DataGridView.

      Case–962829259

      (Defect–4793507)

      This defect fix addresses an issue where the Product Transfer Checking (flowXfer) application was unable to find the product at the pipeline location specified as the destination in the flowXfer record.

      Case–962836196

      (Defect–4865015)

      This defect fix addresses an issue where Pipeline Monitor (PLM) could backfill outage recovery data and raise recovery events before confirming a calculation cycle was valid.

      If a stale or invalid device was later detected, only a partial rollback occurred, leaving inconsistent Historical data, daily totals, and recovery events that could contribute to false PLM deviation alarms.

      Case–962836633

      (Defect–4846540)

      This defect addresses an issue where a PLM volume device associated with a tank lost its configured path as a result of locking contention.

      Case–962869490

      (Defect–4914357)

      This defect fix addresses an issue where Controllers were unable to submit level values in the Tank Scratch Pad using the inch format XX-XX-XX.

      Case–962880761

      (Defect–4960220)

      This defect fix addresses an issue where, when PLM deviation alarms were inhibited due to the hold-off period being in effect, the Inhibit column in the event summary displayed the associated alarm as Uninhibited. With this fix, the Inhibit column now displays Application Specific.

      In the Historical database, this means that the alarmInhibitTypeRefId column in the Event.dbo.OperActivitySummary table will now show a value of 2 instead of 0.

      Case–962890119

      (Defect–4949719)

      This defect fix addresses an issue where dump files were generated during PLM record cloning.

      Case–962896079

      (Defect–5065164)

      This defect addresses an issue where an error was generated when changing an alarm limit on a tank record configured with 16th-inch strap levels. The root cause was a change in the alarm level comparison logic from a string comparison to numeric comparison. This fix reverts the comparison back to string-based comparison to correctly support levels expressed in these fractional inch formats.

      Known issues

      The following known issues were open at the time of this release.

      Description

      Workaround (If Applicable)

      On initial start up of RealTime, unhandled exceptions in ReflexSubscribeCallback may be observed. This behavior does not prevent the normal functioning of the Reflex application.

      None.

      When associated with a Valve object, RealTime failover may log a CompareFieldTypes Business Logic Tier (BLT) failure error while evaluating an Advanced Logic Processor (ALP) expression. This is an intermittent failure and can be observed in the new Standby system after a failover.

      The error is logged when a BLT call is made while the RealTime service is in a premature state and unable to process the PubSub request. This behavior does not prevent the normal evaluation of the ALP expression.

      None.

      If Batch Tracking Compiler (BTC) changes are made to a pipeline while replication to the non-owning site is down, referential issues can cause system alarms to appear on the backup site when the connectivity is restored.

      None.

      A very high flow rate is observed at the accumulator when the associated rate point provides a negative flow rate reading.

      This known issue results from selecting the following values when configuring a Batch Transfer:

      • When configuring the rate record (the record feeding the Accumulator), the record is specified as a telemetered pulse rate that does not have software accumulation enabled.

      • When configuring the Accumulator (the record feeding the Virtual Flow Computer [VFC]), the record is specified with the previous pulse counter (rate) capable of going backwards, a volume accumulation mode that allows positive and negative flow, and a maximum reasonable reverse flow rate (vol/h) that allows backwards flow.

      • When configuring the Batch Transfer, the record is configured using the VFC specified above as a source.

        If the above conditions are true, it is possible for the VFC to interpret a backwards moving pulse rate as negative flow. In addition, because the VFC is attached to a Batch Transfer, it is possible for the Batch Transfer to accumulate a negative volume from an individual device. This will cause the Batch Transfer to show a large value in the following fields: Flowrate, Volume To Go, Measured GSV, and NSV. This is most likely to occur if the negative movement in the pulse rate is observed immediately after a ticket split.

      Confirm that each Accumulator is configured as Positive Only Volume Accumulation Mode to prevent the Accumulator from being able to roll backwards.

      User documentation

      For the AVEVA Pipeline Operations for Liquids 2025 Patch 2 release, only documentation that was directly affected by a defect fix is included. User documentation addendums are no longer included as part of patch deliverables.

      If a document is not listed as updated in these notes, the existing AVEVA Pipeline Operations for Liquids documentation is still applicable.

      The following AVEVA Pipeline Operations for Liquids documents contain updates and are included with this patch:

      • AVEVA Pipeline Operations for Liquids Release Notes (this document) (PDF)

      • AVEVA Pipeline Operations for Liquids Administrator documentation

      The latest versions of all the documentation are available on the AVEVA Documentation Portal and on AVEVA Knowledge & Support Center.

      To view the AVEVA Pipeline Operations for Liquids user documentation on the AVEVA Documentation Portal, sign in using your AVEVA product-support credentials (the same ones used for the AVEVA Knowledge & Support Center).