AVEVA Pipeline Operations for Liquids

Understand validation for a swapped ticket

  • Last UpdatedApr 24, 2025
  • 1 minute read

There are validation checks that may prevent a Batch Swap from being initiated. The conditions that will prevent a Batch Swap include, but are not limited to the following:

  • The Batch Transfer is currently in the process of auto starting another pending ticket.

  • The Batch Transfer Batch Switch on Manual Ticket Start is configured and the Batch Transfer is currently waiting for a field device reset.

  • The Batch Transfer is currently executing an Auto Switch.

  • The Batch Transfer is currently executing a Switch on Volume.

  • The Batch Transfer is currently INHIBITED.

  • The Batch Transfer state is anything other than NORMAL.

  • The Pending Ticket has a Scheduled GSV (Gross Standard Volume) of zero or a negative integer.

  • The Pending Ticket does not have a valid Product Type.

  • The Pending Ticket is no longer in a PENDING state.

  • A maintenance batch is involved in the swap operation. This could happen in one of the following scenarios:

    • The pending batch is a maintenance batch, and the active batch is normal.

    • The pending batch is normal, and the active batch is a maintenance batch.

    • The pending batch is a maintenance batch, and the active batch is a maintenance batch.

    • Pending normal batch and an active maintenance batch.

    • Pending maintenance batch and an active maintenance batch.

  • The active batch was originally a MAINTENANCE batch, and then it was changed to NORMAL.

    Note: If any of the validation checks fail, the Batch Swap will not be initiated and a message informing you of the details displays.