Configure the Anomaly Estimated Time of Arrival (ETA) tab of the Node record

Configure the Anomaly Estimated Time of Arrival (ETA) tab of the Node record

  • Last UpdatedApr 24, 2025
  • 1 minute read

Fields on the Anomaly Estimated Time of Arrival (ETA) Tab on the node Row Edit and the Corresponding Batch Tracking Compiler (BTC) Attributes

BTC Attributes

Anomaly ETA Tab, node Row Edit Form

Description

ANMALM

Alarm Enabled

If selected, an alarm and an event will be generated when the anomaly is received by the specified node. If not, only an event will be generated.

Time Threshold (min)

This field states the anomaly ETA time threshold (in minutes).

If the Alarm Enabled checkbox on the Anomaly ETA tab is selected, AVEVA Enterprise SCADA generates an alarm when an anomaly is the defined number of minutes upstream of the node. An event will always be generated.

Volume Threshold

This field states the anomaly ETA volume threshold.

If the Alarm Enabled checkbox on the Anomaly ETA tab is selected, AVEVA Enterprise SCADA generates an alarm when an anomaly is the defined number of volumetric units upstream of the node. An event will always be generated.

ANMEVT

N/A.

This field has been discontinued. The system will now always generate events.

MERGEANM

Merge Anomaly Enabled

For more information, see Node Record: Batch Tracking Complier (BTC).