DRAGroupUpdate Business Logic Tier (BLT)

  • Last UpdatedApr 24, 2025
  • 2 minute read

The DraGroupUpdate is a Business Logic Tier (BLT) that can be used to update a DraInjectorGroup. Using this BLT, we can enable or disable the Automatic Mode flag of a DraInjectorGroup. This BLT can be used to set a required flow rate range or reset the flow rate range to 0 for a DraInjectorGroup.

The following table details the input parameters for the DraInjectorGroup BLT.

Argument

Type

Description

DraInjectorGroupID

Integer

This integer type is the ptnum for the DRALine that can be obtained from DRALine table in the RealTime (RTDB) database.

changeAutomaticMode

Boolean

Boolean type can be set to True or False. If this field is set to True, it will enable or disable the DraInjectorGroup Automatic Mode field based on the value provided in automaticModeEnabled input.

Note: When this field is set to true, changeFlowRate must not be provided in the input. If both are provided, you will receive an error message that reads:

Only one update can be accomplished per request.

automaticModeEnabled

Boolean

This will reset the Automatic Mode checkbox to enabled or disabled.

This will work only if ChangeAutomaticMode field is set to True and changeFlowRate must not be mentioned.

changeFlowRate

Boolean

The boolean type can be set to True or False when changeAutomaticMode is not provided in the input. If both are provided, you will receive an error message that reads:

Only one update can be accomplished per request.

flowRate

Integer

Refer the DRAFlowRateRange RealTime table to obtain the ptnum for the range required.

Accordingly, the optional parameter will be passed to set the new flow rate range for the selected DRAInjectorGroup.

Changing the flow rate at the level of the DRALineUpdate will override the value in the DRAGroupUpdate.

The following table details the Output parameter for the DRALineUpdate BLT.

Argument

Type

Description

Success

Boolean

Indicates whether the request has been successfully processed.

Message

String

If the request could not be successfully processed, this field will contain a message indicating the reason for the processing failure.

The DRAGroupUpdate BLT can be used to pass the required parameters. Consider the following example where the flow rate to is set to zero and automatic mode is disabled.