AVEVA Pipeline Operations for Liquids

Configure the ProtectedLocation Row Edit: Inhibits tab

Configure the ProtectedLocation Row Edit: Inhibits tab

  • Last UpdatedApr 24, 2025
  • 1 minute read

Use the Inhibits tab in the ProtectedLocation Row Edit dialog to inhibit events and alarms caused by state changes such as change of state from normal to off-normal and vice versa.

The following table details the items on Inhibits tab of the ProtectedLocation Row Edit dialog.

Item

Description

Inhibit LowMode Action

Select to inhibit all violation checking. If no violation checking is in effect:

  • Commands to switch a device in a Protected Location from Low mode to High mode will always succeed.

  • A Protected Location in High mode remains in that mode until the Controller switches it to Low mode, regardless of any actual violations.

Off-Normal Alarm

Select to inhibit off-normal alarming. The system will not generate an alarm when the point changes from a normal state to an off-normal state.

Normal Alarm

Select to inhibit normal alarming. The system will not generate an alarm when the point changes from an off-normal state to a normal state.

Off-Normal Log

Select to inhibit off-normal logging. The system will not log an event when the point changes from a normal state to an off-normal state.

Normal Log

Select to inhibit normal logging. The system will not log an event when the point changes from an off-normal state to a normal state.