Validate a pipeline
- Last UpdatedMay 07, 2026
- 2 minute read
Validate all pipelines in a project to use the pipelines in the s22040 Piping MTO screen.
The Validate Pipeline functionality ensures that the specification values used to define a pipeline are valid when compared to the specifications created in the s81210 Specifications screen.
You can check the following conditions when you validate a pipeline:
-
Ensure the main size of a pipe is a valid size and the main size exists in the s81210 Specifications screen.
-
Ensure the fluid code related to the pipeline is linked to a specification in the s81210 Specification screen.
-
Ensure the corrosion allowance value related to a pipeline matches the specification defined in the s81210 Specifications screen or fits within a fluid code defined in the s22004 Fluid Codes screen.
-
Ensure the design temperature and pressure values of the pipe match the design temperature and pressure values specified for the fluid code related to a pipeline.
-
Ensure the operating temperature and pressure values of the pipe match the operating temperature and pressure values specified for the fluid code related to a pipeline.
Appropriate warning messages are displayed when the conditions listed are not met.
-
Navigate to the s22020 Pipelines screen.
-
In the Current Project control block, from the Project dropdown, select the required project ID.
-
To refresh the screen, select the F5 key.
-
In the Pipelines grid, select a row.
-
On the s22020 menu, in the Validate group, select Validate Pipelines.
-
In the Design Conditions tab, review any warning messages.
-
(Optional) To clear any warning messages, perform the following:
-
Update the relevant fields as required.
-
On the Home menu, in the Record group, select Save.